Digital Workflow in Removable Prosthodontics: A Narrative Review
Department of Prosthodontics and Crown & Bridge, K.D. Dental College & Hospital, Mathura, UP, India
ABSTRACT
The integration of digital technologies has steadily reshaped the way removable prostheses are planned and fabricated. Innovations such as intraoral scanning, CAD/CAM systems, and additive/subtractive manufacturing have introduced alternatives to traditional denture fabrication workflows. Although initial progress was hindered by challenges in accurately recording edentulous tissue details, recent developments have shown improved precision and clinical dependability. This review summarizes the evolution of digital workflows in removable prosthodontics, highlights contemporary protocols for complete and implant-supported dentures, and evaluates the contribution of intraoral scanning along with the use of reference dentures. Current literature suggests that, with suitable case selection and standardized protocols, digital approaches can produce clinical outcomes comparable to conventional methods, while enhancing productivity, reproducibility, and overall workflow efficiency.
Keywords: digital dentures, CAD/CAM, removable prosthodontics, intraoral scanning, implant-supported prosthesis
INTRODUCTION
Conventional removable prosthodontics has traditionally relied on physical impressions, gypsum models, and labor-intensive laboratory steps. While these conventional procedures still produce satisfactory outcomes, they often require several appointments and are susceptible to inaccuracies caused by impression distortion, material handling, and operator-dependent variables. With the advent of digital dentistry, new clinical and laboratory pathways have emerged for examination, planning, and fabrication of removable prostheses.
Digital workflows first gained popularity in fixed prosthodontics because teeth provided stable reference points that facilitated accurate scanning. In contrast, the transition into removable prosthodontics progressed more slowly, largely due to the challenge of recording compressible mucosa, border extensions, and maxillomandibular relationships in edentulous patients. Advancements in scanner technology, design software, and manufacturing systems have now broadened the feasibility of fully or partially digital denture fabrication.
The present review aims to summarize current developments in digital workflows for removable prosthodontics and analyze their clinical practicality as supported by recent literature.
AIM AND OBJECTIVES
Aim:
To examine the current digital workflows utilized in removable prosthodontics and evaluate their clinical significance.
Objectives:
- To trace the development and evolution of digital methods in removable prosthodontics.
- To summarize digital protocols employed for complete denture fabrication.
- To review intraoral scanning techniques applied for recording edentulous arches.
- To describe the application of existing dentures as digital reference tools.
- To highlight the existing challenges and future prospects of digital removable prosthodontics.
EVOLUTION OF DIGITAL TECHNIQUES IN REMOVABLE PROSTHODONTICS
The earliest forms of digital integration in removable prosthodontics began with converting conventional impressions or stone models into digital files using extraoral or laboratory scanners. This digitized information allowed clinicians and technicians to design dentures virtually and fabricate them using computer-controlled milling systems. As the precision of scanning devices and production units improved, CAD/CAM-fabricated dentures gained greater clinical acceptance.
The introduction of additive manufacturing further broadened the scope of digital fabrication by enabling the creation of trial dentures, rapid prototypes, and definitive prostheses through layered fabrication. Digital archiving also made it easier to duplicate dentures, modify design files, and recreate prostheses quickly when repairs or replacements were needed, promoting better long-term patient management.
DIGITAL COMPLETE DENTURE WORKFLOWS
The fabrication of complete dentures using digital techniques can follow either a partially digital pathway or a fully digital workflow. In a partially digital process, conventional impressions and jaw relation records are first made and later digitized through laboratory scanners. Fully digital workflows bypass physical casts and directly capture patient data using intraoral scanners combined with digitally recorded maxillomandibular relations.
Using CAD software, the denture setup can be virtually planned, occlusal schemes modified, and denture bases digitally processed with greater accuracy and repeatability. Several clinical reports indicate that dentures produced through digital methods demonstrate satisfactory retention and stability, with high patient acceptance. Additionally, digital processing often reduces the number of appointments required and minimizes laboratory-related inconsistencies.
INTRAORAL SCANNING OF EDENTULOUS ARCHES
Capturing edentulous arches digitally can be difficult because there are no stable anatomical landmarks and the soft tissues are easily displaced during scanning. Earlier generations of intraoral scanners therefore showed limited precision in edentulous cases, especially when large areas of movable mucosa were involved.
With advancements in scanner technology, along with refined scanning strategies, the accuracy and completeness of edentulous scans have improved considerably. Techniques such as segmented or stepwise scanning help minimize distortion and enhance data stitching. Features like real-time visualization and software-based guidance further assist clinicians in obtaining more consistent and reliable digital impressions.
USE OF EXISTING DENTURES AS DIGITAL REFERENCES
Utilizing the patient's existing denture as a reference model has become a convenient strategy in digital denture workflows. Dual scanning of the prosthesis, both intraorally and extraorally, allows the preservation of key functional and esthetic factors such as vertical dimension, occlusal contacts, and tooth positioning.
This approach is especially valuable for immediate denture procedures or when capturing traditional clinical records is challenging. The pre-existing denture acts as a digital template during design, enabling quicker clinical appointments and improving the overall predictability of the final prosthesis.
Digital Workflows for Implant-Supported Removable Prostheses
Digital workflows have been increasingly incorporated in the fabrication of implant-supported removable prostheses such as overdentures and full-arch rehabilitations. When scan bodies are used, digital impressions enable virtual designing of frameworks and attachment components with improved visualization and planning accuracy.
Although techniques like photogrammetry are still considered the most precise for extensive implant-supported reconstructions, intraoral scanning has shown satisfactory results when applied selectively. In many practices, a combined or hybrid protocol—where digital impressions are supplemented with conventional verification steps—is preferred to enhance the accuracy and long-term success of the prosthesis.
LIMITATIONS AND FUTURE PERSPECTIVES
Although digital methods have enhanced denture fabrication, limitations persist. Accurate recording of functional borders, dynamic soft tissues, and patient neuromuscular adaptation remains challenging. High initial investment, the need for operator training, and restricted software compatibility may limit clinical adoption.
Future developments are expected to focus on improved soft-tissue capture, integration of digital platforms, and AI-driven automation to refine design accuracy and streamline workflows, ultimately making digital removable prosthodontics more predictable and accessible.
CONCLUSION
Digital technology now plays a significant role in the rehabilitation of edentulous patients, enhancing workflow efficiency and accuracy through modern scanning systems, CAD/CAM processes, and additive manufacturing. Although traditional methods continue to hold value, digitally driven workflows present a dependable alternative when case selection and protocols are carefully followed. Ongoing research and clinical trials will be crucial for optimizing these systems and promoting their broader integration into everyday prosthodontic practice.
REFERENCES
- Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: historical development and current status. J Prosthet Dent. 2013;109(6):361–366.
- Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. Concepts and clinical procedures for CAD/CAM complete dentures. J Prosthet Dent. 2012;107(6):351–359.
- Infante L, Yilmaz B, McGlumphy E, Finger I. Digital fabrication techniques for complete dentures. J Prosthet Dent. 2014;111(5):351–355.
- Kattadiyil MT, AlHelal A, Goodacre CJ. Clinical performance and complications of CAD/CAM complete dentures. J Prosthet Dent. 2017;117(4):443–449.
- Kontis P, Güth JF, Schubert O, Keul C. Accuracy of intraoral scanners in edentulous jaws. J Adv Prosthodont. 2021;13(5):316–326.
- Lo Russo L, Sorrentino R, Esperouz F, et al. Evaluation of scanning strategies for edentulous mandibular arches. J Prosthet Dent. 2025;134(1):151–159.
- Kukucka E. Digital reference prosthesis concepts in removable prosthodontics. In: Digital Dentistry: A Clinical Guide. Wiley; 2020.
- Papaspyridakos P, Gallucci GO, Chen CJ, et al. Accuracy of digital implant impressions in edentulous patients. Clin Oral Implants Res. 2016;27(4):465–472.
- Papaspyridakos P, Bedrossian A, Kudara Y, et al. Digital workflows for implant-supported prostheses using reverse scan bodies. J Prosthodont. 2023;32(5):452–457.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Apurva Chaturvedi, Dr. Manesh Lahori, Dr. Siddharth Sisodia. Digital Workflow in Removable Prosthodontics: A Narrative Review. Guident. 2026 Jan;19(2). Available from: https://ivoryindia.in/articles/prosthodontics/digital-workflow-in-removable-prosthodontics-a-narrative-review.html





