Technological development has enabled root canal treatment to become a painless, faster and safer procedure than it was before, providing patients with a greater satisfaction and comfort, translated into economic advantage for the patient as well as the endodontist ,who is under less professional stress, and thus also improved his/her quality of life.

These goals can easilybe reached by professionals who endeavor to follow this technical development in the correlated literature, in courses to recycle and/or update knowledge, and those who are able to acquire the technology, and consequently apply it in the difficult task to performing root canal treatment in an ideal manner.

The new principle of crown/apex root canal instrumentation without pressure, was offered by means of the pioneering OREGON techniques in 1980, and shortly thereafter described by Goerig et al, in 1982. This new preparation principle, which begins in the cervical and middle thirds of the root canal with large diameters files , is complemented with Gates Glidden drills. After this it advances with files in an apical direction, gradually and sequentially diminishing their diameters untilthe working length is achieved. After that the working length is determined. With this technique, root canals are practically clean and conform in taper throughout their full extent.

The crown//down principle without pressure is based on previous studies, by Brilliant & Christei and Coffae & Brilliant, published in 1975and Mullaney in 1979. In subsequent years it was also mentioned by other authors such as De Deus,in 1982, Morgan &Montgomomery , in 1984. Ruiz-Hubaer et al, in 1987 and Valdrighi et al in 1991. This new concept was incorporated into debridement techniques mainly because it avoids extrusion of infected residues, microorganism and their by-products, such as endotoxins, into the periapical area, thus considerably reducing painful post-operative complications, acute apical periododntitis, as well as avoiding the causing flare up, which can seriously affect the image and perception of the patient towards the practitioner.

These techniques are included in the endodontic curriculum in that use the manual technique alone, or as prerequisites for later use of rotary systems.

DO WE REQUIRE ANTI-CURVATURE FILING WHEN PREPARING CURVED ROOT CANALS IN MOLARS ?

The mesio-buccal and mesio-lngual root canals of mandibular molars,particulary of first molars, as well as the mesio-buccal root canal of maxillary molar posses the so called double curvature, which makes it very difficult to perfectly debride ,especially in apical five millimeters. The first curvature, with an initial trajectory in a disto-mesial direction,located at the level of the coronal two-thirds of the roots, and the second curvature at the level of the apical third in the mesial root of mandibular molar and mesio-buccal roots of maxillary molars, their trajectory is reversed; that is, in a mesial to distal direction. The second curvature has a trajectory that has an accentuated curve in a distal direction which occurs in 79% of cases in mandibular molars and in 78% in maxillary molars.

When this double curvature is added to the marked convexity of the mesial wall of the pulp-chamber, theendodontist must be knowledgeable and have the technical resources and skill to overcome anatomic difficulties when performing endodontic treatment. This will allow him/her to easily reach the apical five millimeters, considered to be critical zone in biological endodontics and a challenge to endodontist. Once these anatomic difficulties have been overcome, the endodontist can clean and model the region adequately, as well as disinfect it, if necessary, and perform the three dimensional obturation possible, resulting in a much more favorable prognosis.

In order to overcome this challenge, the compensatory wearing, in the pulp chamber, as well as the anti-curvature filing, at the coronal two-third of the root canal idealized by Abou-Rass et al, are operating procedures of fundamental importance. Compensatory wearing is performed by removing the convexity of the pulp chamber walls, particularly of the mesial wall, which generally covers the entrances of the mesial root canals. Access to the apical part of the root canal will largely depend on the adequate coronal preparation. All root canal systems are curved in one or more planes with the degree and extents of curvature varying from root to root. Elimination of coronal obstruction will greatly enhance the instrumentation procedures in the apical part of root.

Irrespective of the instrumentation technique used, the apical part of the canal system is invariably the least well cleaned and prepared part of the root canal systems. Contrary to the idealized picture ,the morphology of the apical canal is complex and highly variable. Five major apical morphological forms have been described. Experimental clearing of roots has confirmed these variations and underscores the importance of a chemo-mechanical approach to preparation especially in the apical third of the canal systems.

Preparation of the root canal systems requires considerable skills, particularly in cases with more severely curved canals or complex anatomical features. Despite advances instrument design, the experience and tactile skills of the operator remain important. Considerable efforts have been devoted to the study of instrument design and metallurgy in an attempt to produce an ideal instrument; the advances in design have been driven, in part by development of new alloys, and in part by an increase in understanding of the anatomy of the root canal system.

Regardless of the instrumentation procedures or instrument type used, the goals of shaping and cleaning of the root canal systems are:

  • Debridement of the root canal systems;
  • Development of continuously tapering preparations
  • Avoidance of procedural errors


Maintaining the anatomy of the apical constriction during canal shaping is essential for predictable healing of the apical tissue, in addition to mechanically retaining the filling material within the confines of the canal systems. Long term studies have shown improved success rates when instrumentation and filling procedures are maintained within the canal system approximately at the level of the cement-dentinal junction.

Historically, canal preparation technique have included the standardized and serial preparation techniques that focus on achieving a round apical preparation with either a small or minimal taper from apex to coronal aspect of the preparation. In recent decades the concept of the ideal preparations has altered to take into consideration a greater understanding of the natural anatomy of the root canal systems moving away from the more rigid mechanistic approach.

Canal preparation techniques can be broadly divided into those that adopt an ‘apical to coronal’ preparation procedure and those that adopt a ‘coronal to apical’ approach.

NICKEL-TITANIUM: MATERIAL SCIENCE

About 20 years ago, the first fabrication of endodontic instruments from nickel-titanium alloys (NiTi) set in motion a development that fundamentally changed root canal instrumentation forever (Waliaet al1988). The 55 Nitinol (approximately 55% Ni and 45% Ti) still contained traces of iron ( Fe) and cobalt(Co). It was characterized by psuedoelasticity. After loading and unloading, it returns to its initial shape (“memory effect”); however, in the phase change, NiTi exhibits hysteresis with dissipation in contrast with the usual electricity.

There are other “memory” alloys that undergo diffusionless phase change (egCuZnAl,AuCd). This phenomenon also occur during the hardening process of stell:on rapid cooling from a high temperature, carbon (C) has insufficient time to undergo diffusion and anatomic rearrangement of the cubic,surface-centerd austenitic form, and instead it assumes a body-centerd tetragonal structure with volume change. This diffusionless change is referred to as “martensitic change” named after its discoverer, Adolf Martens.

NiTi exhibits virtually no change in volume on cooling and heating, because the twinned martensite and autensite phases are virtually identical in macroscopic measurements. The biocompatibility of Nitinol is very good (Ryhanen et al 1999), and it is used extensively in medicine and dentistry today. The high content of nickel is apparently not problematic because it is bound to titanium and therefore does nor elicits any of the known nickel allergies (Schafer 2002a). However, the manufacturing process is difficult and expensive, and previously often led to inconsistencies.

The low hardness (HV 300-600) and the resultant low cutting efficiency of NiTi in contrast with stainless steel (HV520-540) are outweighed by the ability to use it with a rotary motion. However, the low cutting efficiency of NiTi files also mean reduced longevity. To counteract this advantage, various groups have attempted to improve the surface qualities of instruments, by using nitrides, bromides, or nitrogen ions (Lee et al 1996: Raspisarda et al 2000, 2001). Using the technique of physical vapor deposition Schafer (2002b, c) applies a titanium nitride layer, which led to improved cutting efficiency.

DESIGN OF NICKEL TITANUIM FILES

Permanently rotating instrumentation using NiTi files has been in vogue for almost two decades. But the period of development of such files has a much longer time span. Walia et al (1938) initiated the development by imitating the shape of K-Files.

The first commercially available systems-Lightspeed, MityRoto. Profile, and Power-R-had flattened cutting edges would cut quickly into dentin, leading to wedging and finally to instrument to fracture. In fact, this fear was substaintiated by subsequent studies of fracture rates (Bauman and Roth, 1999)

The file tip and the cutting edges were rounded to provide a non-cutting pilot tip or a “safety” tip. Over time, other more active, shapes were developed. The aggressive cutting by the earliest Quantec files (wedge-from, with 60° and 90°) led to obvious alterations in the internal root canal wall configuration, with massive “elbow” formations(Thompsaon and Dummer,1998).

For the most part, today’s instrument have a rounded tip, and the cutting edges retain their sharpness right up to the tip. The chip space is an important characteristic, as it determines how much debris can before the file become stuck in the canal. Endodontic instrument must therefore posses a blend of desirable characteristic that include flexibility, fracture resistance, and stiffness.

With traditional instrument always had the same chip space, with the development of NiTi instrument, even early on-since 1998 with GT-there an attempt to increase the distance between the flutes, which increased the chip space, reduced the tendency for file wedging during rotation, and permitted more rapid instrumentation. Particularly noteworthy is the alteration between straight and twisted areas in the RaCe line of files. Many instrument today have a progressive distance between cutting edges (eg.,ProTaper,MTwo).

The taper of NiTi files is also an important characteristics; from 0%-“no taper”-in the case of Lightspeed, to the now common 2%, 4%, 6% taper up to even 19%. More recent is the “reverse taper” design, such as ProTaperpr S-Apex instrument, which are thicker at the tip than throughout the body of file. In addition, the same instrument has multiple tapers (f1:7% up to 3mm from the tip, then 5%e.g., ProTaper and the later developed ProTaper Universal)

CROSS SECTION OF NICKEL-TITANIUM FILES

The U-shape has been modified many times and only in 1999 it was presented as a commercial entity in systems such as Hero642,FlexMaster,RaCe,etc,with sharp-cutting modified K-files.

Quantec and K3 looked at the other options with more complex cross-sections. The basic shape of the triangular cross-section with a flattened tip and a u-shape depression was varied in that the central area was enlarged for stabilization, while the cutting surface were made ever sharper, combined with more obliquely oriented surface to remove dentin chips and debris, In subsequent modifications, the basic form was charged to that of an S file or Unifile, and the transverse section modified to resemble a pentagon (Alpha file). Above all, the triangular cross-section permits numerous modifications, many of which are available commercially today. The square cross0section-still common in steel-is found today only in RaCe instruments.

Most recent developments, such as Mtwo, capitalizes on the sharpness of the Hedstrom (H) file design, using –as the name suggested-two cutting surface. The progressively increasing distance (chip space) between the cutting surface from the proximal to the distal end permits a higher level of material transport.

In recent years an, increasing number of file systems have appeared on the market with quite different geometries. During this rapid period of development it has been difficult for the dentist/endodontist and also the various professional organizations to order or categorize the numerous and variable endodotic instrument.

The success of ant NiTi system depends not only on the cutting efficiency of the file, but also to a great extent on the ease of use and the logic behind the file sequence. As early as 2002, Ehrman called for standardization and simplification of the endodontic file coding system.

Although the ISO color coding scheme is still determined by the diameter of the file tip, based on older regulations,the taper of 0-19%, which is often inverse and multiple, is not always easy to comprehend. Thus, the dentist/endodontist is left with an almost innumerable array of file geometries that are often difficult to categorize.

The one helpful factor in this arena of confusion is the commercially available instrument organizers.For mesial root canals of mandibular molars and mesio-buccal maxillary molar root canals, when they are extremely atresic;that is after having been submitted to exploration (apical patency) with regular type k files Nos10/or 15,the use of GG burs and/or instrument with larger taper is recommended after initial preparation or enlargement of the first curvature up to the length that corresponds to the safe area.

This type of preparation is performed with H-files of the number used immediately before the type K file used for the exploration/catheterization of the coronal two-third(half of the root) as performed with a type of K file No.10, it is advisable to initially use a H file No.08. if K file No.15 is used file No. 10 will be indicated.

In this sequence, with kinematics of use previously described, when Hedstom type file No.20 is used, the root canal will be now sufficiently prepared to receive GG burs and/or rotary instruments of larger diameter and tapers.

The use of Gate Glidden bur no.1, especially for beginners, is not recommended due to the high risk of fracture, as has been proven in the endodontic literature. Also it is not recommended its direct use in atresic molar root canals, because the function of the Gate Glidden bur is to widen or to enlarge a previously opened space.

REFERENCES

  1. Abou-Rass M, Frank AL, Glick DH. The anticurvature filing method to prepare the curved root canal. J Amer Dent Ass. 1980;101:792-794.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Anil Dhingra Department of Conservative Dentistry & Endodontics. Instrumentation Techniques and Metallurgy of Endodontic Rotary Instruments. Guident. 2016 Mar;9(4). Available from: https://ivoryindia.in/articles/endodontics/instrumentation-techniques-and-metallurgy-of-endodontic-rotary-instruments.html

Related articles

More in Endodontics

All 308 articles
Vol. 9, Issue 4 · March 2016

Management of Open Apex

Mineral trioxide aggregate (MTA) is a material that has been used successfully in many clinical applications, such as apical barriers in teeth with immature apices, repair of root…

Dr. Panna Mangat

Vol. 9, Issue 5 · April 2016

Working Width in Endodontics -1

Root canal shaping is one of the most important steps in canal treatment. It is essential to determine the efficacy of all subsequent procedures, including chemical disinfection and root…

Dr. Anil Dhingra