Open AccessPeer ReviewedPublished Monthly Since 2007 Vol. 19, Issue 12 · November 2026Media Kitinfo@guident.net
Open AccessCase ReportImplantologySubscribe now

Immediate Implant Placement in Esthetic Zone with Early Loading

  • Dr. Visaahal SinghSenior Lecturer
  • Dr.Shikha PunjaniConsultant Implantologist
  • Dr.Satish Kunwar Department of ProsthodonticsConsultant Implantologist

Vananchal Dental College and Hospital, Garhwa, JH, India

Guident · Volume 8, Issue 10 (September 2015)Published September 20157 min read6 figures

Abstract

Implant placement in aesthetic zone is most challenging in implant dentistry because there are certain relationships between the implant and its adjacent restorations, bone, mucosa, and lip line that result in a service able prosthesis complementary to the natural dentition.The driving philosophy behind current implant/restorative protocols is preservation.

If bone loss occurs gingival architecture will be collapes, which lead to aesthetic compromise and inadequate bone for implant placement. This study aims to determine the success rate of implants placed immediately into fresh extraction sockets, by evaluating clinically and radiographically the soft tissue and hard tissue changes that occur up to 2 years following placement of implants.

INTRODUCTION

Placement of dental implants for replacing missing teeth is a well-established treatment option. Because of its high success rates, implant therapy is being included in treatment plans more routinely. The dental implants provide a realistic treatment alternative for rehabilitation of patients with lost teeth. It provide a healthy dentition with optimal functional efficiency, structural balance and esthetic harmony.1

Loss of a tooth and its replacement with an implant-supported restoration in the aesthetic zone present several challenges when optimal function and esthetics are the goals.2,3,4 The greatest reduction of the alveolar bone occurs after extraction, in the first 6 months to 2 years.5,6 For this reason, in the modern dentistry, the ‘gold standard’ implant treatment protocol has been challenged by experiments, which aimed at shortening the treatment period and by reducing the number of surgical procedures.7 New protocols have been developed in which implants are placed at the time of extraction of the tooth, known as immediate implants.8

The concept of immediate implant loading has recently become popular due to reduced number of surgical treatments, reduction in overall time between tooth extraction and placement of definitive prosthetic restoration, decrease in bone resorption, and preservation of alveolar ridge and increase in patient’s acceptance, along with better function, aesthetics and has a psychological benefit.9 This article presents a comprehensive approach to optimize functional and esthetic results with immediate implant placement in the anterior maxilla.

CASE REPORT

A 20 year old male patient presented to the Department of Prosthodontics, Vananchal Dental College and Hospital with chief complaint failed root canal treated tooth of upper front region. Clinical and radiographic examination revealed failed root canal treated tooth with unfavourable prognosis [Figure 1]. All the available treatment options were discussed with the patient and the proposed procedure which included immediate implant placement and early loading. The patient was very conscious about his aesthetic and was very keen for earliest possible restoration of his teeth and so he opted for proposed procedure.

Pre-surgical radiographic evaluation was carried out with IOPA, panoramic radiograph for appropriate treatment planning. After proper treatment planning endo-osseous implant (Hi- Tec tapered self threaded, Life Care Devices Private Limited, Isreal) measuring 5 × 13 mm in dimension was selected. Atraumatic tooth extraction is the first and one of the most critical steps of immediate implant placement, the fracture tooth was atraumatically removed [Figure 2].After extraction, the site was thoroughly degranulated using curettes, the socket irrigated thoroughly with Povidine- Iodine and carefully examined to be certain that the socket walls were intact. The extraction socket was evaluated for osseous defects. All four walls were found intact. A sequential drilling was carried out with drill sequences of 2.2, 2.8, 3.2, 3.65, 4.3 and 5, implant was placed in socket with the insertion torque of 45 Ncm [Figure 3].Implant first thread was placed 1.5 mm apical to crestal bone of the socket and adequate primary stability was obtained. Post-operative periapical radiograph was taken [Figure 4].

Final impression is made by open window tray technique using with the double-mix impression technique (Virtual VPS putty base, regularset and extra light–body fast set, IvoclarVivadent). Healing cap (Hi-Tec HC-3 gingival former Life Care Device Private limited, Isreal) was secured on the implant. The patient was administered an analgesic (ibuprofen 800 mg, every 4 to 6 hours as needed) for 7 days and a systemic antibiotic (amoxicillin 500 mg, 3 times daily) for 7 days. Furthermore, he was advised to rinse with a 0.1% chlorhexidinedigluconate solution four times a day for 5 weeks.

The impression was poured with type-IV stone (Ultrarock, KalabhaiKarsonPvt.Ltd., Mumbai) and master cast obtained was mounted on a semi adjustable articulator. The working cast was then sent to laboratory for fabrication of CERCON® Zirconia crown (DentsplyCeramco, York, PA). After 2 weeks of healing period, the implant was loaded with cement retained Zirconia crown [Figures 5]. Final cementation was performed with adhesive resin (RelyXUnicem transparent, 3M ESPE, St Paul, MN). Postoperative follow up was done at 15 days, 1 month, 2 months, 3 months, 6 months, 1 year, 1.5 years and 2 years later [Figure 6].

Clinical figure
Figure 1. Pre-operative intraoral frontal view of failed root canal right maxillary central incisor
Clinical figure
Figure 2. Atraumatic extraction of without flap reflection resulted in well preserved bone and soft tissue architecture.
Clinical figure
Figure 3. A 5 × 13 mm tapered self-threaded implant was inserted to desired depth after sequential osteotomy
Clinical figure
Figure 4. IOPA showing implant placement
Clinical figure
Figure 5. Final prosthesis
Clinical figure
Figure 6. The two-year postoperative radiograph confirms favorable conditions at the bone-to-implant interface.

DISCUSSION

Dental implant therapy is one of the recent treatment modality for replacement of missing teeth Immediate implant and early loading may be a good treatment option in the loss of anterior teeth.10 It is seen that the success rate in maxilla is 66%-95.5% and in mandible 90%-100%.11

Aesthetic is one of the a major concern for immediate implant placement, When implant placement is delayed for a period of time after tooth extraction, soft tissue healing may provide opportunities to maximize tissue volume to achieve proper flap adaptation and acceptable soft tissue esthetics. However, this advantage is offset by resorption of bone and loss of ridge dimensions. so prior to extraction of tooth it was aesthetically evaluated to comprehensively assess the potential implant placement site.

Belser, Buser and Higginbottom defined an esthetic implant crown as one in harmony with the perioral facial structures. In addition, the soft tissues, including, height, volume, color, texture and contours, should be in harmony with the surrounding teeth. Finally, the restoration should imitate the natural appearance of the missing tooth.12A proper treatment plan was made which included surgical and restorative protocol to gain the well defined aesthetic goals.

Bone loss after tooth extraction has an importantissue in dentistry. Resorption of the buccal wall of the extraction socket may lead to significant disadvantages, especially in the anterior part of the maxilla. To reduce the problems resulting from this loss of bone, dental implants have been placed into fresh extraction sockets.13

For the success of any.immediately placed implant to succeed, primary (mechanical) stability must be sufficient to enable the implant to resist micromovement until sufficient biologic stability (secondary stability) is adequately established. 14To achieve the sufficient primary stability the minimum insertion screw has to be equal or superior to 32 N/cm and the micro movement of the implant should not exceed 150 um.

To attain good initial stability we selected implants 2 mm longer than the socket length and excess preparation was done 2 mm beyond the socket, with initial drilling followed by sequential drilling15,16so In this case report, primary stability was achieved and no need for bone augmentation and implant is loadedafter 2 week and during 2 years of follow-up there is minimum bone loss occur.

CONCLUSION

Immediate implant placement following tooth extraction has been found to be a viable and predictable solution to tooth loss. This case report demonstrates that it is possible to achieve greater efficiency in our efforts to minimally invasive surgical technique, ease of procedure and shorter time involved together with minimum postextraction complications are the important advantages of this method.

This procedure is technique-sensitive and may be more difficult to executethan the conventional procedure. Therefore, we we should be able to enhance the service and treatment offered to our patients in regard to our treatment time, patient comfort, cost and aesthetics.

REFERENCES

  1. Limor AA, George AZ. Clinical effectiveness of implant supported single tooth replacement. The Toronto study.Int J oral Maxillofac Implants 1996;11:311-21.
  2. Gamborena I, Blatz MB. Transferring the emergence profile of single-tooth implant restorations. Quintessence Dent Technol 2004;27:119–132.
  3. Sadan A, Blatz MB, Salinas TJ, Block M. Single-implant restorations: A contemporary approach for achieving a predictable outcome. J Oral MaxillofacSurg 2004;62:73–81.
  4. Sadan A, Blatz MB, Bellerino M, Block M. Prosthetic design considerations for anterior single-implant restorations. J EsthetRestor Dent 2004;16:165–175.
  5. Carlsson RA, Persson AL. Morphologic changes of the mandible after extraction and wearing of dentures. A longitudinal, clinical and X-ray cephalometric study covering 5 years.Odontologic Review 1967;18: 27-54.
  6. Araujo MG, Sukekava F, Wennstrom JL, Lindhe J. Ridge alterations following implant placement in fresh extraction sockets: An experimental study in the dog. Journal of Clinical Periodontology 2005;32:645-52.
  7. Lazarra RJ. Immediate implant placement into extraction sites: Surgical and restorative advantages. International Journal of Periodontology and Restorative Dentistry 1989;9:333-43.
  8. Adell R, Ericsson B, Lekholm U. A long term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347-59.
  9. Quirynen M, Van Assche N, Botticelli D, Berglundh T. How does the timing of implant placement to extraction affect outcome? Int J Oral Maxillofac Implants 2007;22 (Suppl):203-23.
  10. Ataullah K, Chee LF, Peng LL, Tho CY, Wei WC, Baig MR. Implant placement in extraction sockets: A short review of the literature and presentation of a series of three cases. J Oral Implantol 2008;34:97-106.



More references are availabe on request.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Visaahal Singh, Dr.Shikha Punjani, Dr.Satish Kunwar Department of Prosthodontics. Immediate Implant Placement in Esthetic Zone with Early Loading. Guident. 2015 Sep;8(10). Available from: https://ivoryindia.in/articles/implantology/immediate-implant-placement-in-esthetic-zone-with-early-loading.html

Related articles

More in Implantology

All 224 articles
Vol. 8, Issue 10 · September 2015

Implant Placement by Flapless Technique

Denture or partial prosthesis replace the missing teeth and supporting oral tissues to restore the patient’s ability to eat, speak and improve appearance. Some patients are not satisfied…

Dr .Santosh Kumar R

Vol. 8, Issue 10 · September 2015

Occlusion in Implantology- a Key to Longevity

Osseointegrated implant has become the most upcoming treatment modality of partially and fully edentulous patients. Besides other aspects that form a part of implantology as a science…

Dr. Himanshu Aeran

Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.