Abstract

The displaceable denture bearing tissues or flabby ridges is a common finding in edentulous patients. Unless managed appropriately, such 'flabby ridges' adversely affect the support, retention and stability of complete dentures. Many impression techniques have been proposed to help overcome difficulty .In this article themucostatic impression procedure which records the flabby tissues without displacing is described.This Window impression technique, by Watson uses a custom tray with a window over flabby tissues and a mucostatic impression material to minimize distortion of tissues while making a impression. First, an accurate record of the denture supporting and limiting tissues is made except for the mobile tissues which are recorded in second step using impression plaster material in the window area of special tray.

INTRODUCTION

The performance of a complete denture is often a reflection of its support and retention.1A final impression for a complete denture should 'record the entire denture-bearing area to ensure maximum support, retention and stability.2 However difficulties arise when the quality of the denture bearing areas are not suitable for this purpose. Displaceable, or 'flabby tissues', present a particular difficulty and may give rise to pain or looseness relating to a complete denture that rests on them.3 Published studies indicate that the prevalence of flabby tissues can vary, occurring in up to 24% of edentulous maxillae and in 5% of edentulous mandibles.4 Such flabby tissues could also arise as a result of unplanned or uncontrolled dental extractions.

Liddlelow used two different materials in one custom tray i.e. plaster of paris over the flabby tissues and zinc oxide and eugenol over the normal tissues. 7 Two separate impression trays and impression materials were used to record ‘flabby’ and ‘normal tissues’ separately and then were related intraorally by Osborne. 8 ‘Window’ impression technique was described by Watson.9 He made a custom tray with an opening over the flabby tissues. Normal tissues were recorded by mucocompressive technique by using zinc oxide and eugenol. Once set it was removed and reseated in mouth and impression plaster was painted over the flabby tissues through the window. Watt and Mc Gregor used impression compound over a modified custom tray which was then manipulated to compress the normal tissues while avoiding the displacement of flabby tissues with the same material.10

CASE REPORT

A 78 years old patient reported to the Deparment of Prosthodontics D.Y. Patil-School of Dentistry,NerulNavi Mumbai. The patient complaint of ill fitting upper denture and trouble in eating food. The patient gave history of using the same denture for past 10-12 years. Intra- oral examination revealedupper and lower edentulous arches with flabby tissue in the maxillary arch extending from canine to canine region. The patient requested fora set of new complete dentures. A treatment plan of fabricating a Complete Denture with modification in the impression technique to achieve minimum displacement of denture during function and maximum retention and stability was decided.

METHOD

The primary impression of maxillary arch and mandibular arch was made in irreversible hydrocolloid material Alginate(zhermack) (fig-1) The impression was poured in dental plaster(Kalrock ). The special tray was fabricated after adapting spacer wax on the area of flabby tissue and an additional full spacer. Border moulding was done using low fusing impression compound (DPI PINNACLE). A window was cut in the area of flabby tissue and a final impression was made. Final impression was made in ZnOE impression paste (DPI impressionpaste ). (fig-3) Impression plaster along with anti-expansion powder was used in order to paint the flabby tissues.(fig-4) Beading and boxing was done and final cast was prepared on which denture was fabricated.

Clinical figure Clinical figure
Fig 1: Flabby Tissue in Maxillary Arch Fig 2: Primary Impression made in Alginate
Clinical figure Clinical figure
Fig 3: Window made for Flabby Tissue Fig 4: Impression of Flabby area in Impression Plaster

SUMMARY

Final impression technique using both Zinc-oxide eugenol and Impression plaster for displaceable mandibular residual ridges is described. Impression plaster is chosen because it reproduces good surface details, has excellent dimensional stability and rate of the setting reaction can be controlled by the clinician.

REFERENCES

  1. The glossary of prosthodontic terms J Prosthet Dent 2005;94:39
  2. Carlsson GE. Clinical morbidity and sequelae of treatment with complete dentures. J Prosthet Dent 1998; 79: 17-23.
  3. Xie Q, Nähri TO, Nevalainen JM et al. Oral status and prosthetic factors related to residual ridge resorption in elderly subjects. Int J Prosthodont 1997; 55: 306- 313.
  4. Kelly E. Changes caused by a mandibular removable partial denture opposing a maxillary complete denture. J Prosthet Dent 1972; 27: 210-215.
  5. Lynch CD, Allen PF. The ‘combination syndrome’ revisited. Dent Update 2004; 31: 410-420.
  6. EllisworthKelly.Changes caused by aremovable partial Denture opposing a maxillary complete denture. J Prosthet Dent 2003;90:213-219
  7. Liddelow KP. The prosthetic treatment of the elderly. Br Dent J 1964; 117: 307-315.
  8. Osborne J. Two impression methods for mobile fibrous ridges. Br Dent J 1964; 117: 392-394.

More references are availabe on request.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Gangawane Devika S, Dr. Sardar Charushila S, Dr. Shetty Omkar. Department of Prosthodontics. Stabilizing the Movables. Guident. 2015 Sep;8(10). Available from: https://ivoryindia.in/articles/prosthodontics/stabilizing-the-movables.html

Related articles

More in Prosthodontics

All 386 articles
Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.