Interocclusal Records from Material Selection to Meticulous Application, for Making Restorations with "No Adjustments"
K.D Dental College, Mathura, U.P, India.
Abstract
Jaw relation records are a fundamental and crucial component of providing accurate, high- quality restorations. The exact placement of a maxillary cast in relation to a mandibular cast on an articulator is governed by the properties of the material used to record a specific intraoral position of the mandible to the maxillae. It is necessary to classify the use of the various interocclusal recording media, to define and describe their optimal working and handling properties, and to evaluate their accuracy in terms of application.
The success of a fixed prosthesis is closely dependent on the the precision with which the interocclusal record is made and the type of material chosen in case of different clinical situations. Over the years, various materials have been used. Proper impressions and mounting of casts can reduce or eliminate that challenge. With appropriate interocclusal records we can give better and precise restoration with “no adjustments”. This article discusses the use of various interocclusal record materials and techniques according to various clinical situations.
INTRODUCTION
Jaw relation records are a fundamental and crucial component of providing accurate, high- quality restorations. A disciplined and efficient practitioner understands that the use of accurate records minimizes the need for intraoral adjustments before prosthesis delivery and can therefore reduce overall treatment time and cost.1
The exact placement of a maxillary cast in relation to a mandibular cast on an articulator is governed by the properties of the material used to record a specific intraoral position of the mandible to the maxillae. It is necessary to classify the use of the various interocclusal recording media, to define and describe their optimal working and handling properties, and to evaluate their accuracy in terms of application.2
After the maxillary cast has been accurately affixed to the articulator by using a facebow, the mandibular cast must be exactly oriented to the maxillary cast.3
Impression materials have generally been used to record the maxillomandibular relation. The material used to record this relation is largely responsible for the accuracy of the record.4
FUNCTION OF THE INTEROCCLUSAL RECORD
- They provide the stability or support that the casts of the remaining dentition lack,
- they reduce chair time for the delivery of the restoration,
- they reduce the likelihood of making restorations in hyperocclusion or without occlusal contacts, and
- they reduce the chance of perforation of restorations being inserted with excessive adjustment or having to adjust the opposing dentition inappropriately.
CLASSIFICATION
Based upon the remaining vertical support of the dentition, interocclusal records used to mount casts in maximum intercuspation can be separated into two categories:
- records made when a tripod of vertical support is available from the remaining tooth-to-tooth contacts (a record made in the presence of an existing tripod) and
- records made when a tripod of vertical support is not available from the remaining tooth-to-tooth contacts (a record that must create a tripod).
THE EXISTING TRIPOD INTEROCCLUSAL RECORD
- When a tripod of sufficiently spaced contacts and good tooth intercuspation are present, no interocclusal record is required.
- For patients undergoing prosthodontic treatment, with poor intercuspation before treatment there is lack of horizontal stability may be the result of the loss of teeth, worn or flattened occlusal surfaces, and/or the preparation of those teeth undergoing prosthodontic treatment. In these situations, the opposing casts cannot be positively articulated in a reproducible position without the use of an interocclusal record.
Materials that can be used in such cases-
- Elastomeric materials such as vinyl polysiloxanes and
- Polyethers are well suited for making interocclusal records where only horizontal stability is needed.
In contrast to nonresilient materials, elastomeric materials can be placed between teeth that have opposing tooth contacts. For the purpose of making existing tripod records, these materials can be used in locations where there is space between opposing teeth because the vertical support between the two casts should be supplied by the dentition.
Unlike records made from elastomeric materials, records made from rigid materials such as waxes, resins, pastes, and plasters should not be placed between teeth that have opposing tooth contacts because this could easily result in the inadvertent increase of the VDO or lateral displacement of the mandible.
Additionally, many of these materials are fragile in thin section and may break when handled. When a rigid material is used to make an existing tripod record, space for the record should be available between prepared teeth and their antagonists or between teeth without interocclusal contacts.
THE CREATED TRIPOD INTEROCCLUSAL RECORD
There is lack of acceptable tripod of vertical support when:
- opposing teeth are present in desired tripod stop locations but without tooth-to-tooth contact at one or more of the stops;
- a tripod of opposing teeth making occlusal contact is present but is not adequately spaced within the arches; or
- opposing teeth are absent at one or more desired tripod stop locations.
In such cases, the interocclusal record is used to create an adequately spaced tripod of vertical support between the two casts.
Materials that can be used in such cases- In circumstances in which well positioned teeth are present but do not contact their antagonists, a record with some thickness needs to be made. The materials best suited for this purpose are those that are soft at placement and then become rigid before their removal from the mouth.
Examples are:
- Waxes,
- resins,
- zinc oxide
- Eugenol pastes and non-eugenol zinc oxide pastes,
- and impression plasters.
These materials can be placed between few or many teeth, and may be placed alone or in combination with other materials (for example, resin/ paste, wax/paste, or resin/wax combinations).
The choice of the material used to make this type of record and the design of this record are largely dependent upon the clinical conditions present and the preferences of the practitioner.5
INTEROCCLUSAL RECORD MATERIALS
Over the years, various materials and methods have been introduced to accurately record the orientation of the working casts. Most commonly used materials are:
Wax. Most waxes used for making an interocclusal record are heated before use. Heating wax relaxes the stress and strain in the material, but the residualmemory of the wax often causes its distortion as it cools.
Some waxes need not be heated before making an Interocclusal record such as Coprwax is an example. This wax is a firm material, but it allows relatively easy indentation of teeth in a room-temperature state. Multiple jaw closures in the desired jaw relationship are made into the wax,checking indentation of the teeth each time, to assure reproducibility of the closure position.
Zinc oxide-eugenol pastes:
Popular for many years in the past, these pastes are not used significantly today. Although these materials can be used for making a record, they have many negative characteristics including brittleness, poor taste, odor, burning sensation, long setting time and a tendency to fracture when any small “positive” discrepancy is present on the cast. They can still be used adequately, but there are better materials.
Non-eugenol pastes:
These materials were introduced to eliminate the taste and burning characteristics of ZOE pastes, and they do that admirably. However, they still have the other negative characteristics of zinc oxide-eugenol pastes.
Silicone putty:
These materials, very popular in the ’70s, can make an excellent interocclusal if used properly. Usually two pastes are mixed manually or by automixing syringes and placed on teeth that have been prepared. The patient is advised to bite into the unset interocclusal record material. If there is no deviation of the mandible during closing, this interocclusal record method is acceptable.
Polyether:
This material is very accurate and stable, but it is also bitter to taste, extremely rigid when set and difficult to cut and shape after set. An example polyether product, Ramitek (ESPE-Premier), is relatively easy to use and acceptable.
Silicone paste, nonslumping:
In recent years addition-reaction silicone, made in a form that has very little flow when mixed, has dominated the IOR market. The most popular product is Blu- Mousse, Parkell. Other, similar products include Blue-Velvet, Aurium/Dyna Group Inc.; Bite Registration Cream, GC America; and Correct VPS (Vinyl Poly Siloxine), Jeneric/ Pentron.
Each of these materials has very low flow when mixed. Overall, non-slumping silicone pastes that become rigid after setting are state-of the- art interocclusal materials.6
TECHNIQUES TO IMPROVE INTEROCCLUSAL RECORD:
Double-arch impressions:
Indication:
Double-arch impressions not only are as good as but may be better than full-arch casts for single units.
Procedure:
The procedure for making an optimum double arch impression is as follows:
- Carefully analyze the occlusion for prematurities.
- Eliminate any obvious prematurities that cause deviation in the slide from centric relation to maximum intercuspation, leaving the slide from centric relation to maximum intercuspation smooth, straightforward and intact.
- Make the double-arch impression in mandibular position. The double-arch impression usually is made in maximum intercuspation, which is one reason why the interocclusal relationship usually is quite accurate. On mandibular closure, saliva and debris are forced from the occlusal surfaces, which is not the case in a full-arch impression. Such interdigitation of the arches duringthe impression leaves the occlusal table relatively clear of inaccuracies potentially caused by debris, air bubbles or saliva remaining on the tooth surfaces.
- Use a double-arch tray. Double-arch trays should have very thin, non–water-absorbing interocclusal wafers, as well as a wide facial-lingual dimension between the supporting sides. The teeth, palate or bony tori can cause narrow supporting sides to deviate. The tray should extend from the most distal tooth to include at least the canine on the side of the arch being treated. The tray should have minimal and nonintrusive supporting sides, with an extremely thin connector on the most distal end of the tray to allow for accurate closure into maximum intercuspation.
- Observe for proper mandibular closure. The clinician should observe the closure pattern of the jaw before making the impression, ensuring that he or she knows the patient’s exact closure pattern and visually recording the contact of the canines on the opposite side of the arch.
- Choose the appropriate type and viscosity of impression material preferably a medium viscosity material syringed around the tooth preparation(s) and heavy-bodied material in the tray to ensure the stability of the set impression.
- Ensure proper mandibular closure. Guide the patient into maximum intercuspation position and observe the contact of the teeth on the opposite side of the arch for accuracy.
- Pour casts. Pour the prepared side of the impression first, allow it to set, lubricate the die areas and then pour the opposing side and mount the casts to a small hinged articulator.
Accuracy. A single unit or as many as two units fabricated properly with this technique seldom need any adjustment at the seating appointment.7-9
FULL-ARCH IMPRESSIONS
There are situations in which double-arch impressions are not indicated.
Among them are the following:
Patients who have worn away the canine rise and incisal guidance of their teeth by means of bruxing often have no stable maximum intercuspation position. In such cases, full-arch impressions are indicated, and full-arch casts should be mounted in centric relation for optimum predictability. Some occlusal adjustment is needed on seating such restorations.
With a few exceptions, when more than two teeth are prepared or missing, occlusal stability in maximum interdigitation is difficult to obtain. (When almost all of the teeth are present, it is relatively easy to retain occlusal stability, even if one or two teeth are prepared.) In such cases, full-arch impressions and casts are more stable and preferable.
A patient with many missing teeth, or an unstable occlusion caused by mobile teeth or any other apparently unpredictable occlusal situation, is better treated with full-arch impressions and full-arch casts.
Interocclusal records for full-arch casts.
Most dentists have been taught to use various material between the two arches to register the proper interdigitation of the arches in centric relation. Most often, clinicians use heavy-bodied vinyl polysiloxane or some form of wax to accomplish this. Subsequently, the clinician places this full-arch interocclusal record between the maxillary and mandibular casts and mounts the casts on an articulator.
When many teeth have been prepared or are missing, this is one of the only ways in which to mount the casts. However, the use of this technique in cases in which only a few teeth (three or four) have been prepared or are missing has aroused controversy. Many schools teach the use of an interocclusal wafer that fits all around the arch, whereas others have supported a piecemeal interocclusal record that is placed only where the teeth have been prepared or are missing.
Patients with many missing teeth or an unstable occlusion because of mobile teeth or other situations also require the full-arch impression and full-arch cast.
Preferred technique for a three-unit fixed prosthesis is as follows:
- Observe the occlusion carefully for prematurities.
- Eliminate any obvious prematurities that cause the slide from centric relation to maximum incuspation to deviate. When making a three-unit fixed prosthesis for a person who has a normal, stable occlusion without any visible pathosis, leave the centric relation-maximum intercuspation slide present and construct the prosthesis to fit into the long-established healthy occlusion with the slight shift remaining.
- Decide on the mounting position. Do you prefer to mount the casts in centric relation or in maximum interdigitation? For simple three-unit situations, maximum interdigitation is preferred because it is a stable, easily identified, reproducible and comfortable position.
- When the fixed prosthesis is returned from the laboratory and before cementation, adjust any retrusive prematurities from centric relation to maximum interdigitation.
- After tooth preparation is complete and impressions are taken, ask the patient to close the mouth into maximum interdigitation and observe tooth contacts all around the mouth.
- Make the piecemeal interocclusal record. Place the medium of your choice on only the areas that have been prepared and have the patient close into maximum interdigitation. rigid vinyl polysiloxane is preferred, which is made especially for interocclusal records.
- Let the material set, trim it and send it to the laboratory to be used for mounting the casts.
- In cases in which it is needed (such as a long -centric or wide-centric occlusion), right and left lateral check bites can allow semiadjustable setting of condylar inclination and Bennett movements.
Accuracy of the step by step inter-occlusal record technique for three or four units.
Accomplished correctly, this procedure will produce optimum occlusion with minimal or no adjustment of the fixed prosthesis. However, there are potential challenges with this technique.
Among them are the following:
- If the patient exerts too much occlusal force on the interocclusal record material and the tooth preparations for the prosthesis have removed posterior stops for the occlusion on that side of the arch, there is a possibility, albeit small, that the mandible will overclose.The resultant prosthesis will be “too low.”
- Positive stone bubbles on the casts may not allow the casts to come together properly. A too high prosthesis will result.
- Using high-expansion mounting plaster or stone may open the occlusion and cause discrepancies in mounting the casts, thus making the prosthesis too high.
- The clinician should trim the interocclusal record so that it touches only the occlusal surfaces of the involved prepared teeth. Any record material extending onto soft-tissue areas will not allow optimum accuracy, usually relating to a prosthesis that is too high.
- The clinician must hold the maxillary and mandibular casts together tightly when mounting them on the articulator. Any lack of stone-to-stone contact between the maxillary and mandibular casts of the unprepared teeth will result in a prosthesis that is too high.8
SUMMARY
The success of a fixed prosthesis is closely dependent on the the precision with which the interocclusal record is made and the type of material chosen in case of different clinical situations. Over the years, various materials have been used. Proper impressions and mounting of casts can reduce or eliminate that challenge. With appropriate interocclusal records we can give better and precise restoration with “no adjustments”.
REFERENCES
- Rachel S. Squier Jaw relation records for fixed Prosthodontics Dent Clin N Am 48(2004) 471-484
- Phillip L. Millstein , R Ernest Clark Differential accuracy of silicone-body and self-curing resin interocclusal records and associated weight loss J Prosthet Dent 46(4) 380-384
- Lucia VO Centric relation: theory and practice. J Prosthet Dent 1960; 10:849-856
- Berman, M.H. Accurate Interocclusal Records J Prosthet Dent 1960; 10:620
- Freilich MA, Altieri JV, Wahle JJ. Principles for selecting interocclusal records for articulation of dentate and partially dentate casts. J Prosthet Dent 1992;68:361–7.
- Gordon J. Christensen Keeping Interocclusal Records: How to solve a common problem. JADA, Vol. 124, April 1993
- Hahn SM, Millstein PL, Kinneunen TH, Wright RF. The effect of impression volume and double-arch trays on the registration of maximum intercuspation. J Prosthet Dent 200;102(6):362-367.
- Gordon J. Christensen Improving interocclusal records for crowns and fixed prosthesis JADA 142(4) April 2011
- Gordon J. Christensen Ensuring the accuracy and predictability with double-arch impressions. JADA 2008;139(8):1123-1125.
More references are availabe on request.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Manesh Lahori, Dr. Divya Sachdev Department of Prosthodontics. Interocclusal Records from Material Selection to Meticulous Application, for Making Restorations with "No Adjustments". Guident. 2015 Sep;8(10). Available from: https://ivoryindia.in/articles/prosthodontics/interocclusal-records-from-material-selection-to-meticulous-application-for-making-restorations-with-no.html