Cai-CAD-CAM Concept in Dentistry
Department of Prosthodontics & Implantology, K. D. Dental College & Hospital, Mathura (U.P) India
ABSTRACT
CAD/CAM technology was introduced to the dental community in the early 1980s. Fusing CBCT and CAD/CAM technologies seems to be the right path to follow if wanting to improve accuracy and predictability in surgical dental treatments The technology, which is used in both the dental laboratory and the dental office, can be applied to inlays, onlays, veneers, crowns, fixed partial dentures, implant abutments, and even full-mouth reconstruction.
Another great advantage about using a digital approach is time reduction in surgical procedures, thus decreasing patient morbidity significantly.
This article discusses the CONCEPTS of CAD/CAM CAI in dentistry and gives an overview of how it works.
KEYWORDS – CAD, CAM, CAI, DIGITAL DENTISTRY, INTRAORAL SCANNERS, CBCT
INTRODUCTION
The dental digital workflow can be divided into three global steps, regardless the process involved; either for surgical, prosthodontic or orthodontic use.
Each step has to be carefully addressed in order to achieve a precise outcome.1
Errors in the initial phase can lead to serious mistakes, despite meticulous treatment planning. Said steps in the digital workflow refer to:
Computer-Assisted Imaging (CAI): It is the initial step of the process and stands for digital data acquisition. Although often disregarded, this stage is critical to ensure a reliable result. While digital planning seems to be easygoing, no software will indicate if the uploaded data is erroneous, altered or does not match patient clinical situation. Therefore, special considerations have to be taken into account for the optimization of the image capturing procedure.
Computer-Assisted Design (CAD): It represents the surgical virtual planning stage and uses a dental software. A huge variety of these computer programs can be found, from license restricted to license free; from simply image viewers to advanced planning software. They serve as great tools for diagnosis and treatment planning and additionally, allow to export data to help accomplish the desired outcome. The designing phase demands expertise and therefore, a time-consuming training.
Computer-Assisted Manufacturing (CAM): To translate the virtual plan to the analog and tangible scenario, a device needs to be manufactured.
Moreover, ad hoc tools, such as specific surgical drills, are necessary during the clinical procedure. Also, a special software is needed to control the machines in charge of the manufacturing process. This step is usually trusted to the dental technician, as it implies additional equipment.2
1. CAI
Acquiring reliable digital data from the patient is fundamental for accomplishing a correct diagnosis and a trustworthy treatment plan.
For that means, clinicians need to obtain 2 types of data: surface scans from patient oral cavity and medical images from the underlying tissue anatomy.
Surface Scans (STL Files)
Whenever there is a need of fabricating prosthetic restorations, surgical templates, or any other device that demands a correct fit in the oral cavity, jaw replicas are necessary to undertake said processes.
The original STL file was created for a vintage stereolithography CAD software by 3D Systems.
Despite originally been named as an abbreviation of “stereolithography”, STL has also other backronyms, such as “Standard Tessellation Language” or “Standard Triangle Language”, as it uses triangle forms to represent the shape of the object.
FIG 2 (a) Standard Triangle Language (STL) stands for the reconstruction of an object based on triangular forms.
(b) Surface scan in DCM format (left) and STL format (right). This DCM file is used by 3Shape® to add features such as color. When transforming this file into a plain STL file, only surface topography remains. Although not altered, the scan loses metadata.
Two methods for digitalizing patient dental arches are nowadays available: intraoral and extraoral scanning.3
On one hand, impression materials have been used to record teeth surfaces and its surrounding areas for a long period of time; improving accuracy, hydrophilic properties, and volume stability through time.
Following this method, physical stone models can be created and then digitilized with an extraoral scanner to obtain a digital file. On the other hand, a direct digitalization of the oral cavity can be accomplished with intraoral scanners, avoiding conventional impression techniques and thus, improving accuracy, saving time and easing patient experience FIG 3.
Intraoral Scanners
The implementation of intraoral scanners (IOS) in dentistry comes along with the development of CAD/CAM systems and enhances the digital workflow, providing fluency and precision. It also aims to reduce operative and treatment time, improve communication with laboratories, and reduce unnecessary storage space.2
Optical, non-contact intraoral scanners are devices comparable to portable cameras used to record the surface of the oral topography. This camera needs to project a light (as it works in a dark environment) and record the oral situation within an integrated sensor, either as individual images or as a video.
Extraoral Scanners
Dental technicians use a desktop laboratory scanner to digitalize stone casts or even conventional dental impressions. This turns out to be a perfect solution if not having an IOS in the dental office.4
Extraoral scanners (EOS) can be subdivided into two types: contact or contact-less. While the first refers to former digitalizing methods (i.e., Procera®, Nobel Biocare), non-contact or optical scanners are widely used today.
Initially, contact or mechanical scanners used a probe to go across the object surface to detect its morphology.
Naturally, the size of the probe and the angle of incidence influence scanning accuracy.
Former contact scanners.
Nowadays, optical scanners rely on a ray of light or laser to illuminate the object and collect information of the tridimensional surface using triangulation principles . The light projected onto the object is reflected and captured by the receptor unit. The sensor measures the angle of the reflected light and so calculates the 3D data by means of triangulation principle (FIG 6).
C. Triangulation principle. A light is projected over an object and the reflection is captured by a camera. The angle of reflection is measured to determine the surface of the scanned object (FIG 6).
CBCT Images (DICOM Files)
DICOM comes from Digital Imaging and Communications in Medicine and it is considered to be the standard for sharing and management of medical imaging information and related data. In other words, DICOM is the extension file exported from a medical equipment after performing a study.5
CBCT visualization in conventional JPG file, (a) and in software viewer (DICOM file manipulation). Panoramic curve, slices and 3D rendering can be customized and the study can be navigated to get as much information as possible (b) FIG 7.
CAD: Computer-Assisted Design
In digital implant dentistry, two different kinds of software packages can be found. Therefore, each dental program can be catalogued either as a prosthetic planning software or an implant planning software. While the first ones are used mainly by dental labs, the second ones are used by clinicians to visualize CBCT images, plan implant placement, and design surgical templates.5,6
Planning Software
Even though both programs (prosthetic and surgical software) are basically CAD programs (as they are set to design), the term “CAD software” in dentistry normally refers to the group of technology used to design restorations, bite splints, abutments, and other prosthetic elements. It is important to differentiate between prosthetic planning software and implant planning software.1,2,6
CAD Workflow
Although every CAD program has its own characteristics, all systems offer the user a similar workflow.
Job definition: This can seem an insignificant task but has all to do with path selection. Site specifications regarding crown/bridge virtual design, implant distribution and guided or non-guided surgery are usually the available options among the software.5,7
File uploading: Depending on job definition, the program will ask the user to upload a CBCT image and/or a surface scan. As said before, if a virtual wax-up or a guide fabrication is not necessary, an STL file will not be demanded. Nevertheless, additional files can be uploaded to have more patient information.
File cropping: This step reduces volume information, especially in extended DICOM images, helping the clinician focus on site evaluation and also reducing memory used to navigate and store the project. Special attention should be kept on leaving enough dental structures in the cropped DICOM file to merge with the STL.
Panoramic curve definition: when examining a CBCT, a panoramic curve that goes throw the center of the bone ridge at a crestal level has to be drawn. This serves for determining the axial views where the virtual implant will be placed.
Mental nerve definition: Whenever planning an implant in the mandible, this is a necessary step to verify implant security distance during its placement.
Virtual Wax-Up: Positioning a tooth provided by the library and adapting it to the desired clinical situation comes prior to implant placement, as the intention of this protocol is to deliver an implant that is prosthetically driven.7,8
This step can appear before or after CBCT image manipulation (crop, panoramic curve and mental nerve definition) (FIG 8).
Image Merging: While some programs offer automatic matching, this step usually requires identifying anatomical points present in both STL and DICOM files. Correct merging is one of the key steps for achieving a good outcome.
Implant Placement: Implant selection and positioning throughout CBCT axial slices, together with emergence profile assessment towards the future crown demands same expertise as conventional implant placement.9,10
Guide Fabrication: As with conventional splints, retentive areas should be avoided in order to properly fit the template. So, insertion axis is determined within the software to visualize these areas and draw the contour of the future guide.
Confirmation and File Export: Normally, a surgical report containing the drilling sequence and the virtual planning is delivered to the user (or the surgeon if designed by a third party), to be checked and confirmed.
FIG 9: Guide fabrication. Insertion axis determination from an occlusal view (a). Shadow areas indicate retentive zones to be avoided with the design (b). Guide contour delimitation (c) and inspection windows added to assess proper fit (d).
CAM
The manufacturing process represents the procedure used to materialize what has been digitally designed into a tangible object. There are two main ways to achieve this: either by subtractive or additive methods.10,11
Subtractive Methods
During subtractive manufacturing methods, an object is created by removing material from a solid block using burs or a variety of cutting tools. As the final outcome comes from the material block, mechanical characteristics of the raw material can be expected to be preserved. Capability to reproduce complex anatomy will depend on the type of milling machine used.12,13
3-Axes Vs. Multi-Axes Machines
Main difference between these two groups consists in the possibility of reproducing complex topography and smooth angles. While 3-axes machines allow movement only in the handpiece, 4/5-axes machines allow movement both in the handpiece containing the bur and the plate holding the material. As its name goes, 3-axis machines provide a cutting tool that moves in 3 linear aspects (left-right, back-forth, and up-down) and therefore, certain areas of the design might be impossible to reach. In contrast, 4/5-axes machines allow all regions from the design to be reached and so, reproduce more detailed and complex objects.12,14,15
FIG 10: 3-Axes milling machine from Sirona Dentsply(Cerec 3®) (left). Only the handpiece can move and so, certain areas cannot be reached. 5 Axes milling machine from Sirona Dentsply (inLab® MC X5®) (right).
The material is attached to a moving baseplate, allowing a combination of movements that helps the creation of smooth angles and divergent structures.
Additive Methods Although milling processes offer accuracy and high-quality materials, 95% of templates used in static guided surgery are fabricated with additive methods. This is mainly because of its lower cost, compared to the subtractive method.
Also, low maintenance and space-effectiveness make 3D printers suitable for in-office purposes. Objects printed with a desktop 3D printer are usually ready overnight while orders placed to professional services or dental labs with larger machines are ready for delivery14,16,17 within 2 to 5 days.
3D Printer Types
A huge amount of 3D printers exists, as they are used for industrial purposes to manufacture any kind of products. To reduce the specter to the ones that have dental applications, categorization will include 4 groups.15,18
CONCLUSION
To summarize, the first important step is to acquire digital data from patient anatomy while minimizing volume alterations and maximizing surface definition (CAI). Next, the information is uploaded into a dental software where the virtual surgery is performed and the whole planning is confirmed (CAM). Afterwards, data is exported to a machine which creates a physical object to be used prior or during surgery (CAD).7,8,17,18
It is important to outline that the clinician can interact and participate actively in every phase or trust some steps to a third party. Nevertheless, knowledge of the whole process is mandatory to ensure a predictable outcome.
REFERENCES
- Alghazzawi TF. Advancements in CAD/CAM technology: options for practical implementation. J Prosthodont Res. 2016;60(2):72–84.
- Richert R, Goujat A, Venet L, Viguie G, Viennot S, Robinson P, Farges JC, Fages M, Ducret M. Intraoral scanner technologies: a review to make a successful impression. J Healthc Eng. 2017;2017:8427595.
- Al-Hassimy H, Al-Hassimy H, Al-Hassimy A. Review of the intraoral scanners at IDS 2019. Cologne: Institute of Digital Dentistry
- Vercruyssen M, Fortin T, Widmann G, Jacobs R, Quirynen M. Different techniques of static/dynamic guidad implant surgery: modalities and indications. Periodontol 2000. 2014;66(1):214–27.
- Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hämmerle CH, Tahmaseb A. Computer technology applications in surgical implant dentistry. A systematic review. Int J Oral Maxillofac Implants. 2009;24(Suppl):92–109
- Tahmaseb A, De Clerck R, Wismeijer D. Computer-guided implant placement: 3D planning software, fixed intraoral reference points, and CAD/CAM technology. A case report. Int J Oral Maxillofac Implants. 2009;24(3):541–6.
- Ortega-Martínez J. Polyetheretherketone (PEEK) as a medical and dental material. A literature review. Med Res Arch. 2017;5(5):1–16. Mora MA, Chenin DL, Arce RM. Software tools and surgical guides in dental-implant-guided surgery. Dent Clin N Am. 2014;58(3):597–626.
- Vercruyssen M, Laleman I, Jacobs R, Quirynen M. Computer-supported implant planning and guided surgery: a narrative review. Clin Oral Implants Res. 2015;26(Suppl 11):69–76.
- Oh JH, An XL, Jeong SM, Choi BH. Digital workflow for computer-guided implant surgery in edentulous patients: a case report. J Oral Maxillofac Surg. 2017;75(12):2541–9.
- Razavi T, Palmer RM, Davies J, Wilson R, Palmer PJ. Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography. Clin Oral Implants Res. 2010;21:718–25.
- Aranyarachkul P, Caruso J, Gantes B, Schulz E, Riggs M, Dus I, Yamada JM, Crigger M. Bone density assessments of dental implant sites: 2. Quantitative cone-beam computerized tomography. Int J Oral Maxillofac Implants. 2005;20:416–24.
- Bryant JA, Drage NA, Richmond S. Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system. Dentomaxillofac Radiol. 2008;37:365–74.
- Pauwels R, Araki K, Siewerdsen JH, Thongvigitmanee SS. Technical aspects of dental CBCT: state of the art. Dentomaxillofac Radiol. 2015;44(1):20140224.
- Januário AL, Barriviera M, Duarte WR. Soft tissue cone-beam computed tomography: a novel method for the measurement of gingival tissue and the dimensions of the dentogingival unit. J Esthet Restor Dent. 2008;20(6):366–73.
- Hedesiu M, Baciut M, Baciut G, Nackaerts O, Jacobs R, SEDENTEXCT Consortium. Comparison of cone beam CT device and field of view for the detection of simulated periapical bone lesions. Dentomaxillofac Radiol. 2012;41(7):548–52.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. C. Pradeep, Dr. Manesh Lahori. Cai-CAD-CAM Concept in Dentistry. Guident. 2021 Mar;14(4). Available from: https://ivoryindia.in/articles/prosthodontics/cai-cad-cam-concept-in-dentistry.html