Open AccessPeer ReviewedPublished Monthly Since 2007 Vol. 19, Issue 12 · November 2026Media Kitinfo@guident.net

Quality of Dental Impressions and Cast Sent to the Dental Laboratory

  • Dr. Prakyath MalliSenior Lecturer
  • Dr. Sanath ShettyProfessor & Head
  • Dr. Shashin AcharyaP.G. Student

Department of Prosthodontics Yenepoya Dental College, Mangalore

Guident · Volume 12, Issue 4 (March 2019)Published March 20197 min read3 figures

Abstract

The ultimate aim of any clinician is to provide optimum fixed prosthesis to their patients. Although the all clinicians are well trained to make impressions, it is not a rare occurrence to have errors in an impression. It is also essential to note that in the Indian dental practice scenario, clinicians without any additional or specific specialized training in crown and bridge are legally entitled to fabricate fixed prostheses for their patients. It must also be noted that, a large section of the dental laboratory usually in the sub urban and rural India are still operated by an unorganized and self-trained dental technicians. Thus it becomes imperative to evaluate the quality of the impressions and dental casts produced by clinicians practicing in India and also assess the quality of prosthesis that may be produced from these records. This is an initial report of a study that was designed to gather data on the quality of dental impression and working casts that are sent to the dental laboratory with an objective of understanding the quality of prosthetic work that is sent to the laboratory’s and also to create awareness about the importance of enhancing individual skills through specialized training to enable the clinicians to provide their patients with fixed prosthesis of optimum quality.

Although there is a general consensus on what constitutes a good impression or a good quality cast, there seems to be lack of intent or skill in achieving it. The findings of this study indicates the need for additional training of clinicians on critical evaluation of impressions made by them, continued training for lab technicians, and improved communication with the lab.

INTRODUCTION:

Prosthodontics is a demanding discipline with many clinical and laboratory procedures. The quality of impressions and working casts sent to commercial laboratories for the fabrication of fixed prosthesis has direct and definite impact on the quality of restoration that are provided to the patients. The fundamental principle of fixed prosthodontics is to provide esthetically and functionally optimum fixed prosthesis to their patients that can co-exist with healthy, harmonious periodontium, and that do not cause any deleterious damage to the adjacent hard and soft tissue1,2.

Most clinicians in India still use a traditional impression approach, and it is important that the impressions are evaluated to ensure that it is of acceptable quality before they are sent to a laboratory, to fabricate a well-fitting, clinically acceptable crown. The quality of the impression can affect the fit of the crown and bridges, and some prosthesis must be remade, leading to increased chair time for both the patient and the dentist, as well as increased operational costs for the practice. It is not uncommon even for an experienced clinician to have errors in their impression. Nachum Samet et al 2005; clinically evaluated impressions made for fixed partial dentures and they found that 89.1% had 1 or more observable errors. Significant correlations were found between material type and voids or tears at the finish line and between material type and polymerization problems.3 Singh B P et al 2013; in their cross sectional survey found that 71.29% laboratories presented that most casts were not articulated, 66.20% of impressions received were not accurate enough to do their best work, less than 25% of the casts were disinfected, 65.74% were not sending work authorization forms and most of them were not appropriate.4

This study thus aims to assess the quality of impressions and casts sent to the dental laboratory, with an objective to evaluate the clinical detectable errors in the impression and working cast sent to laboratories.

METHODOLOGY:

500 impressions and working cast for fixed prosthodontics were examined from various dental laboratories, using simple random sampling with the consent of the lab head. The impressions or the working models received were qualitatively evaluated for the detectable errors by two calibrated investigators. The evaluation was done using a validated self-structured pre-formed survey proforma. The practitioners were categorized into 3 groups as prosthodontist, other specialists and general dentists. The investigators recorded the nature of work, tray selection, errors in impression material, errors in recorded impression, and errors in detected in the working cast. The permission to conduct the survey was obtained from the university ethical clearance board.

Only dental laboratories operated by qualified technicians were approached and only Impressions or working casts received for Crown and bridge fabrication were included for evaluation.

The collected data was analyzed using Pearson- Chi- square test, with the significance level (p<0.05)

RESULTS:

500 sample which included impressions and working cast for fixed prosthodontics were examined, out of which 69% were working cast and 31% were impressions.

41 % of the work received was from general dentists, 36%, from Prosthodontists and 23 % from other specialists .

On comparing the errors in impression among the three groups the results showed that highest number of errors in impression were among the other specialty group(12.1%) followed by general dentists(7.4%) as shown in Graph 1.

On comparing errors in working casts general dentist were found to have significantly higher number of errors as shown in Graph 2 and 3.

DISCUSSION:

In the present study, 69% of the samples were working cast and 31% were impressions. This percentage also were high in other survey conducted in India. Reason stated by the authors is that most of the dentists prefer using alginate as a material of choice for impression and the casts have to be poured immediately.

The result of the study indicates that the practitioners prefer to send working cast to the dental laboratory, this could be because, though the ideal impression materials for making impressions in Fixed Partial Denture is elastomeric, Alginate still continues to be one of the most commonly used impression materials for various reasons such as the ease of use and cost of materials. This requires that the impressions should be poured before they can be sent to the laboratory for fabrication of the prosthesis. Jankar et al5also reported a similar finding.

On comparing the errors in impression among the three groups the results showed that highest number of errors in impression were among the other specialty group, followed by general dentists. Study by Samet N3 found that 89% of impressions contained errors in the registration of the preparation, which potentially could affect the accuracy of the restorations. Saifudin et al6, stated that unacceptable impressions is a serious concern, as it contributes to the inaccuracy of the crown and bridgeworks provided to patients. Unfortunately, these errors may go unnoticed or maybe ignored for lack of chairside time or probable lack of skill. Many factors may influence the quality of prosthetic work produced in our practices, which may include, the lack of knowledge and experience, poor manipulation of the impression material, lack of attention to details, low awareness on the need of critical self evaluation or even financial constraint could be the possible underlying reasons for these unacceptable impressions being sent to the laboratory.

On comparing the errors in the working cast, it was found that among the 3 groups, the general dentists group showed highest errors. The quality of the master cast seems to be one of the main reasons for poor quality of restoration, it is dependent on the materials used, technique of pouring and the knowledge of the person pouring the cast, which unfortunately is poured by untrained clinical assistants.

CONCLUSION:

Although there is a general consensus on what constitutes a good impression or a good quality cast , as clinicians we need to critically evaluate the overall procedure, train the laboratory assistants, build effective communication with the laboratory technicians, update our skills with current techniques and trends.

Graph 1

Clinical figure

Graph 2

Clinical figure

Graph 3

Clinical figure

REFERENCES:

  1. Padbury Jr A, Eber R, Wang H-L. Interactions between the gingiva and the margin of restorations. J. Clin Perio 3; 30:379–385.
  2. Aimjirakul P, Masuda T, Takahashi H, Miura H. Gingival sulcus simulation model for evaluating the penetration characteristics of elastomeric impression materials.,Int. J. Prosthodont 2003;16:385–389.
  3. Samet N, Shohat M, Livny A, Weiss EI. A clinical evaluation of fixed partial denture impressions. J Prosthet Dent. 2005;94(2):112-117.
  4. Singh BP,Singh K,Singh N, Agrawal KK, Kumar L,Kumari R.Current Trends and Practices Followed by Dental Technicians and Dentists in Fixed Crown and Bridges in India: A Cross-sectional Survey.International Journal of Prosthodontics and Restorative Dentistry, 2013;3(2):43-49
  5. Amruta P. Jankar et al Impression materials and techniques used and followed for the fixed partial denture treatment by private dental practitioners in Maharashtra state: A questionnaire study International J. of Healthcare and Biomedical Research, Volume: 04, Issue: 03, April 2016, 83-92
  6. Saifudin et al, The quality of working impressions for the fabrication of fixed prosthodontics prostheses (crown and bridgework). Eur J Gen Dent 2014;3:100-4.

Disclaimer from Guident

The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.

How to cite this article

Dr. Prakyath Malli, Dr. Sanath Shetty, Dr. Shashin Acharya. Quality of Dental Impressions and Cast Sent to the Dental Laboratory. Guident. 2019 Mar;12(4). Available from: https://ivoryindia.in/articles/prosthodontics/quality-of-dental-impressions-and-cast-sent-to-the-dental-laboratory.html

Related articles

More in Prosthodontics

All 386 articles
Vol. 12, Issue 4 · March 2019

Principles of Tooth Preparation: Part-4

PREPARING A MARGIN IN DIFFICULT TO ACCESS AREAS OF THE ORAL-CAVITY One of the primary concerns when working in difficult to access areas of the oral cavity or in patients with decreased…

Dr. Moez I. Khakiani

Vol. 12, Issue 5 · April 2019

The Concept of Shade Guides

To effectively overcome the challenges associated with accurate shade selection in aesthetic restorative dentistry, it is essential for dentists to understand both the science and art of…

Dr. Rohit Bansal

Vol. 12, Issue 5 · April 2019

Principles of Tooth Preparation: Part-5

MANDIBULAR MOLAR PREPARATION FOR A PFM CROWN Tooth preparation for a Porcelain Fused to Metal (PFM) restoration needs to provide adequate room to accommodate for the metal substructure, the…

Dr. Moez I. Khakiani

Call for papers

Publish your clinical work in Guident

Original research, case reports and review articles are welcomed from clinicians and researchers worldwide. Every submission is assessed by the editorial board.