Understanding the Implant Related Nerve Injuries...from Damage to Repair and from Prevention to Care.
K.D Dental College, Mathuta, U.P, India
INTRODUCTION
Nerves are fragile and can be damaged by pressure, stretching, or cutting. Trigeminal nerve injury is the most problematic consequence of dental surgical procedures with major medico-legal implications. These injuries have a significant negative effect on the patient’s quality of life and the iatrogenesis of these injuries lead to significant psychological effects.
Causes of inferior alveolar nerve injury include
- Local anaesthetic injections;
- Third molar surgery;
- Implants;
- Endodontics;
- Ablative surgery;
- Trauma; and
- Orthognathic surgery
REVIEW OF LITERATURE
From the literature, the incidence of inferior alveolar nerve (IAN) injury following removal of third molars has been reported to be 0.26% to 8.4%, of which 0.81% to 5.7% are transient and 0.7% permanent.
Lingual nerve (LN) sensory disturbance is typically reported between 0.1% and 8% with transient injury as high as 23%. A recent study showed permanent damage in more than one-third of injured trigeminal nerve injuries.
Libersa and colleagues investigated transient versus permanent injuries sustained during various procedures, with a notable 75% incidence of implant-related nerve injuries being permanent.
CLASSIFICATION
- Seddon broadly classifies by severity using descriptors that include neuropraxia axonotmesis, and neurotmesis.
SUNDERLAND FIRST-DEGREE INJURY
Table 1 The Seddon and Sunderland classiï¬ cations of nerve injury
| Seddon | Process | Sunderland |
| Classification of nerve injury | ||
| Neurapraxia | Segmental demyelination | First degree |
| Axonotmesis | Axon severed but endoneurium intact (optimal circumstances For regeneration) | Second degree |
| Axonotmesis | Axon discontinuity, endoneurial tube discontinuity, perineurium and fascicular arrangement preserved | third degree |
| Axonotmesis | Loss of continuity of axons, endoneurial tubes, perneurium and and fasciculi; epineurium intact (neuroma in continuity) | Fourth degree |
| Neurotmesis | Loss of continuity of entire nerve trunk | Fifth degree |
SUNDERLAND FIRST-DEGREE INJURY
- Is an insult resulting in conduction blockade following nerve traction or mild compression. Axonal continuity is maintained.
- Sensory disturbances are expected to be transient, lasting a few months or more.
Axonotmesis (Sunderland second-degree injury) is more severe, with wallerian degeneration occurring distal to the site of a crush injury. Axon regeneration can occur because the endoneurium remain undisrupted. Complete recovery occurs normally within several months, but may take 1 year or longer.
SUNDERLAND THIRD-DEGREE
- A more severe crush or traction injury produces a Sunderland third-degree injury that disrupts the fascicular endoneurium. Complete axonal regeneration is hampered, and a form of permanent sensory disturbance is expected.
SUNDERLAND FOURTH-DEGREE INJURY
Sunderland fourth-degree injury additionally disrupts the perineurium with the likelihood of fibrosis, scarring, or neuroma formation further impeding regeneration efforts.
SUNDERLAND FIFTH-DEGREE INJURIES
- Neurotmesis and Sunderland fifth-degree injuries result from complete transection of the peripheral nerve structure, including epineurium, perineurium, and endoneurium.
- Complete anesthesia occurs in the distribution innervated by the specified nerve.
- Neuropathic pain syndromes can occur, with spontaneous nerve regeneration being unlikely.
CAUSES OF NERVE INJURY
MECHANISM OF INJURY
Inferior alveolar nerve injury during traumatic local anaesthesia injection
Local anaesthetics prevent sensory impulses being transmitted from intraoral and extraoral areas to the central nervous system with minimal effect on muscular tone. Unfortunately, the injury of an IAN can occur during a traumatic local anaesthesia injection. Although very rare, nerve injury after administration of an IAN block was well documented. The exact mechanism of the injury has yet to be determined, nevertheless. Three main theories were proposed. These include direct trauma from the injection needle, hematoma formation and neurotoxicity of the local anaesthetic.
One of the oldest theories is that the needle contacts the nerve directly, thereby traumatizing the nerve and producing a prolonged change in sensation. Performing mandibular block the practitioner contacts bone with the tip of needle to ensure a proper deposition of local anaesthetic and the tip of this needle can become barbed. In one study, 78% of the long bevelled needles used for conventional mandibular block appeared to be barbed at their tips after the procedure, regardless of bevel placement.
These barbs can rupture the perineurium, herniate the endoneurium and cause transection of the multiple nerve fibres and even entire fascicles, especially on withdrawal. Only 1.3 – 8.6% of the patients get an “electric shock type†sensation on the application of IAN block and 57% of the patients suffer from prolonged neuropathy, having not experienced the discomfort on injection, thus this is not a specific sign. The second theory is the needle may traumatize the epineurial blood vessels. Haemorrhage from the epineurial blood vessels would compress the nerve fibres and cause localized neurotoxicity.
The damage could be extended beyond 30 minutes after injection. The release of blood and blood products from the epineurial blood vessels into the epineurium during hematoma formation would lead to reactive fibrosis and scar formation, applying pressure to and inhibiting the natural healing of the nerve. The third theory suggests that the anaesthetic itself causes localized chemical damage to the nerve, if it is injected intrafascicularly or becomes deposited within the nerve as the needle is withdrawn.
Inferior alveolar nerve injury by implant drill
- Implant-related nerve injuries can be from:
- drilling the osteotomy,
- placement of the implant,
- or both.
The most severe types of injuries are caused by implant drills and implants themselves.
Sensory IAN injuries made by implant drills may be caused by
direct intraoperative (mechanical and chemical) and
indirect postoperative trauma (ischemia and thermal stimuli).
INFERIOR ALVEOLAR NERVE INJURY BY DENTAL IMPLANT
Sensory IAN injuries made by dental implant may be caused by direct intraoperative (mechanical) and indirect postoperative trauma (ischemia) or periimplant infection. Direct mechanical injury i.e. encroach, transection, or laceration of the nerve is related to implant intrusion into the mandibular canal.
AREAS OF CONCERN
First Bicuspid Region, Anterior Loop of Mental Branch
- Radiographic and cadaveric evidence indicates that an anterior loop of the mental branch exists. Its size and how often it is present are not clear.
- Greenstein and Tarnow associated both radiographic and cadaver dissections and found that radiographs provide many false-negative and false-positive findings.
- There was poor correlation between radiographic and cadaver studies. They determined that the size of the loop from cadaver dissections ranged from 0.5 to 3.31 mm.
- The investigators recommended 2-mm clearance coronal from an area of suspected anterior loop, as shown
- The anterior loop region is of concern when placing implants in the first premolar or between the first and second premolars. It also is a consideration when planning angled implants for fixed-hybrid cases
- In these cases the distal implants are strategically angled around the mental foramen to increase the anterior-posterior spread.
- The presence and size of the anterior loop becomes a factor in treatment planning these cases.
- Intraoperative direct visualization of the mental foramen is helpful in placing the distal implants. However, if a loop of significant size is present, the apex of the implant may cause injury even though the coronal aspect of the implant is at a safe distance from the mental foramen.
- Appropriate radiographic imaging is useful in planning these cases.
Second Premolar, Mental Foramen Region
- The second premolar region is of concern because of the proximity of the mental foramen. The mental foramen is located inferior to the second premolar 73.8% of the time according to cadaver studies.
- The second most common location is between the first and second premolars.
- This finding is of importance when planning implants in this region, especially immediate implants in a second premolar extraction socket.
- When placing an implant in this region, overdrilling the preparation intentionally, for primary stability of an immediate implant, or unintentionally in a healed site may cause direct trauma to the contents of the mental foramen.
Posterior Mandible Associated with Atrophy
- Many patients have missing posterior mandibular teeth with a dentate anterior segment. Conventional prosthodontic treatment of this situation usually involves fabricating a bilateral distal extension partial denture.
- Patients subsequently present for implant evaluation after significant atrophy of the posterior ridges occurs causing loss of denture stability
Anterior Maxilla, Nasopalatine Nerve
- Although not common, implant-related nerve injuries can also occur in the anterior maxilla, involving the nasopalatine nerve. The injury could occur where the neurovascular bundle traverses the nasopalatine canal or where it exits the incisive foramen in the anterior maxilla.
STRATEGIES TO AVOID INJURY
- Local Anesthesia Administration
- When placing mandibular implants, it is not necessary to administer an inferior alveolar block injection for adequate local anesthesia. The primary advantage of not giving a block injection is that the patient has some awareness and perception around the IAN.
- If the site preparation is drilled too close to the neurovascular bundle, the patientmay be able to provide feedback to the surgeon. In addition, not giving a regional block injection eliminates the risk of a needle-stick injury to the IAN trunk.
- If the patient has numbness following implant placement with an IAN block administered, there is confusion about the mechanism of injury because of the possibility of a needle-stick injury, unless there was evidence of direct nerve injury during the procedure
- Local infiltration provides sufficient anesthesia to place an implant with either flap or flapless techniques.
- Studies have shown there to be no statistically significant difference in patients’ comfort having an implant placed under local infiltration versus regional block injection.
- The reason for this is that implants are typically placed in poorly innervated healed or grafted extraction sockets, and the sensory innervations to the mandible are primarily from the periosteum. Marrow innervation is scant primarily in the venous sinuses.
- The profound pulpal anesthesia that is essential for restorative tooth preparation or tooth extractions is not necessary for implant placement.
-
Short Implants
- Another strategy to avoid implant-related nerve injury is to use shorter implants in areas where the available vertical height is minimal superior to the IAN canal. The use of short implants has been studied and shown to have mixed outcomes.
- Some studies report an increased failure rate compared with standard-sized implants. Other investigators describe acceptable results when used in the appropriate situation and adhering to recommended technique. The use of short implants is a valid approach to place implants in the posterior mandible providing that the bone quality is suitable for primary stability.
BONE AUGMENTATION TECHNIQUES
- In atrophic situations in which implant placement would encroach on the nerve canal, bone augmentation procedures may provide enough space for safe fixture placement.
- There are several procedures available to augment atrophic alveolar bone to provide the appropriate 2-mmsafety zone from the IAN
- These procedures include
- distraction osteogenesis techniques,
- onlay bone grafting,
- interpositional sandwich grafting, and
- grafting using a barrier such as a titanium mesh.
- One important caveat about bone augmentation procedures is that they may only be used in situations in which there is sufficient interarch space for both the bone graft and a crown on the implant.
- It is common to have supereruption of the opposing arch limiting the interarch space.
- Bone augmentation in this instance limits or even precludes the placement of an abutment and crown on the implant. In this type of situation, a nerve lateralization procedure could be considered as alternative method of placing an implant without decreasing an already limited interarch space.
NERVE LATERALIZATION PROCEDURES
- Nerve lateralization is a useful procedure to facilitate the placement of implants in atrophic posterior mandibles.
- This procedure makes available dense cortical bone inferior to the IAN canal for stable implant placement. Because thin knife-edge ridges can be removed and the implant can be placed more inferiorly, onlay bone grafting is rarely necessary.
- Although useful, the procedure is more involved and requires skill and experience with manipulating nerves. This requirement likely limits its use in routine practice.
- Nerve lateralization involves decortication of the lateral cortex over the course of the inferior alveolar canal, and usually the mental foramen with anterior extension of the decorticated area to expose the incisive branch of the IAN
- The incisive branch is usually sectioned to permit mobility of the inferior alveolar trunk and mental branch, which allows the trunk and mental branch to be moved laterally. Once the nerve is repositioned, implants are placed in the center of the alveolus, medial to the repositioned nerve .
- The implants are placed as deep as necessary, including into the inferior border as required for stability. The defect from the decortication can be grafted, and the nerve trunk replaced laterally. Some surgeons prefer to protect the nerve trunk with a type I/III collagen tube or polyglycolic acid tube.
- After nerve lateralization surgery, patients experience neurosensory disturbance; however, it has been shown to be transient in most individuals.
- In a study by Hashemi, the mean time to full recovery of sensory function was 37 +- 15 days.
- Only 3% of the patients studied had prolonged disturbance beyond 1 year. Although patients do have transient hypoesthesia following nerve lateralization, it remains a reliable procedure if other methods failed or are not an option because of limited interarch space.
MANAGEMENT OF IMPLANT-RELATED NERVE INJURIES
CONCLUSION
Meticulous diagnosis and treatment planning are the key to success to avoid implant related complications including implant related nerve injuries. Proper understanding of the involved anatomy, the surgical procedures, and implant systems—along with proper treatment planning—will reduce the chances of such an unpleasant complication. If nerve injury occurs, early and proper management is the key to maximizing the chances of recovery.
REFERENCES
- Inferior alveolar nerve injury associated with implant surgery Clin. Oral Impl. Res. 24, 2013 / 183–190
- Implant related nerve injuries Mark J. Steinberg, DDS, MDa,b, Patrick D. Kelly, DDSc,*Dent Clin of North America
- Libersa P, Savignat M, Tonnel A. Neurosensory disturbances of the inferior alveolar nerve: a retrospective study of complaints in a 10-year period. J Oral Maxillofac Surg 2007;65(8):1486–9.
- Worthington P. Injury to the inferior alveolar nerve during implant placement: a formula for protection of the patient and clinician. Int J Oral Maxillofac Implants 2004;19(5):731–4
- Scher EL. Use of the incisive canal as a recipient site for root form implants: preliminary clinical reports. Implant Dent 1994;3(1):38–41.
- Greenstein G, Tarnow D. The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review. J Periodontol 2006;77(12):1933–43.
- Hashemi H. Neurosensory function following mandibular nerve lateralization for placement of implants. Int J Oral Maxillofac Surg 2010;39(5):452–6.
- Heller A, Shankland W. Alternative to the inferior alveolar nerve block anesthesia when placing mandibular dental implants posterior to the mental foramen. J Oral Implantol 2001;27:127–33.
- Heller A, Shankland W. Alternative to the inferior alveolar nerve block anesthesia when placing mandibular dental implants posterior to the mental foramen. J Oral Implantol 2001;27:127–33. Romeo E, Bivio A, Mosca
- Alhassani A, AlGhamdi A. Inferior alveolar nerve injury in implant dentistry: diagnosis, causes, prevention, and management. J Oral Implantol 2010;36(5): 401–7.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Manesh Lahori, Dr. Divya Sachdev Department of Prosthodontics. Understanding the Implant Related Nerve Injuries...from Damage to Repair and from Prevention to Care. Guident. 2015 Dec;9(1). Available from: https://ivoryindia.in/articles/implantology/understanding-the-implant-related-nerve-injuries-from-damage-to-repair-and-from-prevention-to-care.html