CT Guided Implant Mandibular Overdenture with Magnetic Att Achments in a Severely Atrophic Ridge
Abstract
For many years, open-field aluminum–nickle–cobalt magnets have been used in prosthodontics, but limited success has been achieved because of their susceptibility to corrosion by the saliva. Also their retentive force is weaker relative to the initial retention offered by mechanical attachments. Magnets made from alloys of the rare earth elements samarium and neodymium provide stronger magnetic force per unit size. In addition laser-welded containers have improved protection from salivary corrosion. The magnetic attachments have immense application because, unlike mechanical attachments, they have potential for unlimited durability and might therefore be superior to mechanical ball or bar attachments for the retention of removable prostheses on implants such as overdentures.
Key Words – Magnets, overdentures, retentive force
INTRODUCTION
One often meets patients who present with dentures which have no appreciable residual ridge and therefore very little support and retention. Secondly a decreased physiologic ability to manipulate the denture in the oral environment. This is a sorrowful situation in which we find many of our patients. Fortunately the implant supported overdentures holds new hope for the edentulous patients. Implants may be placed in planned specific sites and their number may be determined by the restoring doctor and patient. Various types of attachments systems can be used with overdentures, magnetic attachments being one. This article describes a CT guided implant mandibular overdenture with magnetic attachments.
CASE REPORT
A patient reported to the clinc with a loose mandibular denture. A decision was made to fabricate overdenture with magnetic attachments, a CT scan based implant scanning and guided execution of this case was carried out. The guided planing software Implant Smart was used to pre determine the accurate prosthetically driven position of the implants. Radiographic markers, guttaPercha was used to predetermine the accurate position of the implants based on the final and natural prosthetic outcome of the definitive restoration. The surgical guide with firm anchor pin stabilization was fabricated. Two implants were placed in the canine region using the flapless surgery technique. Standard procedure was followed for making the dentures, relief holes were provided in the mandibular denture for placement of the magnetic assemblies. The magnetic keepers were attached to the implants. The fit checker was used to confirm that the magnetic assemblies would fit in the prescribed spaces. Magic Fit IP (magnetic attachments for implants) was used as it connects to the existing implant system and offered all the benefits of standard magnetic attachments. The magnetic assemblies were set on to the keepers and spillways were made in the denture to allow for surplus resin during installation of the magnetic assemblies. The holes were filled with self cure resin and the denture was inserted into the patient’s mouth paying special attention to the position of the magnetic assemblies and keepers. The patient was advised to close on the lower dentures till the resin had set.
DISCUSSION
There has been a rapid stride in the field of CT and cone beam (CBCT) imaging, interactive treatment planing software, minimally invasive flapless oral implant surgery with guided surgical procedures and CT derived templates. CT imaging helps clinicians improve all aspects of implant reconstruction, including both restorative and surgical phases while diminishing complication of malpositioned implants.
In this particular case, magnetic attachments were used over the implants. The magnetic assembly contains the magnet inside and is set in the denture base. The keeper is magnetically attracted to the magnetic assembly and is attached to the implant. Additional retention is thus provided by the attraction between the magnet in the dentures and keepers on the implant.
The features of magnetic forces are as follows
1.Constant retentive force
The retentive force is not decreased over time because the material characteristic of the permanent magnet is used.
2.Attractive force acts primarily in the vertical direction at right angles to the attractive face of magnet.
The magnetic coupling thus becomes easily dissociated by any harmful lateral and rolling forces and so reduces lateral loading of tooth root or implant.
3.Retention after slight disengagement of the magnet and keeper.
An overdenture retained using magnetic attachments is easy to insert and remove and so has widespread application for older patients who need nursing care and disabled patients and patients with reduced manual dexterity.
The clinical advantages of the magnetic attachment is as follows
- Superior esthetics
The magnetic attachment has esthetic benefits because there are no visible parts such as clasps.
- Protect the abutment teeth from harmful lateral and rolling forces.
- Easy insertion and removal
- Cleaning is easy
- Fabrication is easy.
Structure of magnetic attachment
There are two types of commonly used magnetic assembly structures: - the sandwich type and the cap type. The magnetic assembly is made from Neodymium Iron Boron rare earth magnet that is covered by stainless steel. This is corrosion resistant and is sealed by laser welding. The keeper is made of magnetic stainless steel and is corrosion resistant. When the magnet and keeper are in contact there is a closed magnetic circuit and the attractive force of the closed magnetic circuit is about four times greater than that of an open magnetic circuit.
Variety of magnetic attachments
1. Cast Coping
2.MAGFIT RKR
Flat type and Dome type
3.MAG FIT SX2
Self adjusting function
REFERENCES
- Riley MA, Walmsley AD, Harris IR. Magnets in prosthetic dentistry. J Prosthet Dent. 2001;86(2):137-42.
- Riley MA, Williams AJ, Speight JD, Walmsley AD, Harris IR. Investigations into the failure of dental magnets. Int J Prosthodont. 1999;12(3):249-54.
- Saygili G, Sahmali S. Retentive forces of two magnetic systems compared with two precision attachments. J Oral Sci. 1998;40(2):61-4.
- Akaltan F, Can G. Retentive characteristics of different dental magnetic systems. J Prosthet Dent. 1995;74(4):422-7.
- Highton R, Caputo AA, Pezzoli M, Matyas J. Retentive characteristics of different magnetic systems for dental applications. J Prosthet Dent. 1986;56(1):104-6.
- Tokuhisa M, Matsushita Y, Koyano K. In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability. Int J Prosthodont. 2003;16(2):128-34.
- Ishikawa M, Kashiwabara T, Ishida O, Ichikawa T. Installing magnetic keepers using LASER welding. J Prosthodont. 2002;11(1):49-52.
- Hiroshi I. Clinical analysis on the reliability of the magnetic attachment over an 8 year period. In: Ai M, Shiau YY, editors. New magnetic applications in clinical dentistry. Tokyo: Quintessence International; 2004. p. 93-6.
- Honkura Y. The new generation of dental magnetic attachment. In: Ai M, Shiau YY, editors. New magnetic applications in clinical dentistry. Tokyo: Quintessence International; 2004. p. 51-56.
- Naert I, Alsaadi G, Quirynen M. Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: a 10-year randomized clinical study. Int J Prosthodont. 2004;17(4):401-10.
- Cune M, van Kampen F, van der Bilt A, Bosman F. Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial. Int J Prosthodont. 2005;18(2):99-105.
- Burns DR, Unger JW, Elswick RK Jr, Giglio JA. Prospective clinical evaluation of mandibular implant overdentures: Part II – Patient satisfaction and preference. J Prosthet Dent. 1995;73(4):364-9.
- Assad AS, Abd El-Dayem MA, Badawy MM. Comparison between mainly mucosa-supported and combined mucosa-implant supported mandibular overdentures. Implant Dent. 2004;13(4):386-94.
- Davis DM, Packer ME. Mandibular overdentures stabilized by Astra Tech implants with either ball attachments or magnets: 5-year results. Int J Prosthodont. 1999;12(3):222-9.
- Chu FC, Deng FL, Siu AS, Chow TW. Implant-tissue supported, magnet-retained mandibular overdenture for an edentulous patient with Parkinson's disease: a clinical report. J Prosthet Dent. 2004;91(3):219-22.
- Laurell KA, Gegauff AG, Rosenstiel SF. Magnetic resonance image degradation from prosthetic magnet keepers. J Prosthet Dent. 1989;62(3):344-8.
- Hiroshi Mizutani - Basic clinical manual of magnetic overdenture : Quintessence Publishing.
- MacEntee MI, Walton JN, Glick N. A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-supported complete overdentures: three-year results. J Prosthet Dent. 2005;93(1):28-37.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Ashish Kakkar, Dr. Kanupriya Kakkar, Dr. R. C. Kakkar, Dr. Ashish Kakkar Sr. Consultant Dr. Kanupriya Kakkar Consultant Dr. R. C. Kakkar Sr. Consultant. CT Guided Implant Mandibular Overdenture with Magnetic Att Achments in a Severely Atrophic Ridge. Guident. 2013 Dec;7(1). Available from: https://ivoryindia.in/articles/implantology/ct-guided-implant-mandibular-overdenture-with-magnetic-att-achments-in-a-severely-atrophic-ridge.html