Implants Retained Maxillofacial Prosthesis - a Glimse into Future
Kandivali (E) Mumbai (India)
Abstract
The face is the most noticeable part of the human body . . . . . . IT IS THE GOD GIVEN RIGHT OF EVERY HUMAN BEING TO APPEAR HUMAN.
Key words :-Implant, Maxillofacial prostheses.
INTRODUCTION
Before few years, mechanical undercuts and adhesives are used for mechanical retention, but, the prosthetic restoration of dentoalveolar and maxillofacial defects has significantly improved with development of new materials and advances in clinical, surgical and lab techniques1,2,3.(FIGURE-1)
FIGURE - I MAXILLOFACIAL PROSTHESES
ROLE OF IMPLANTS IN MAXILLOFACIAL PROSTHESIS
Branemark P I (1977) and his associates were pioneers.The prosthetic restoration of dento-alveolar and maxillofacial defects has significantly improved with development of new materials and advances in clinical, surgical and lab techniques.
FIGURE – II DENTAL IMPLANTS FOR MAXOLLOFACIAL PROSTHESES
FIGURE – III DENTAL IMPLANTS FOR MAXOLLOFACIAL PROSTHESES
AURICULAR DEFECTS - IMPLANT DESIGNS
The replacement of missing ear can be attempted surgically and prosthetically by an array of techniques. The replacement of missing ear can be attempted surgically and prosthetically by an array of techniques. 2-3 implants are sufficient for satisfactory retention. Tjellstrom et al – ideal position of implants have to be 18-20 mm from the center of the external auditory meatus.
According to Tolleth, three measurements are very important.
FIGURE – IV EAR IMPLANTS
AXIS
Its difficult to define axis. It’s a line of balance through the long dimension of the ear. Parallel to the bridge of the nose. Angulation of 20 degrees from the vertical position seems to be satisfactory.
LEVEL
The level can be assessed with the head in the anatomic vertical position. The highest part of the helix is on a line roughly with that of the eyebrow, and the lowest part of the lobule is on the line at the base of the columella or slightly below that.
DISTANCE FROM THE ORBIT
The ideal distance of the prosthesis from the lateral orbital rim is about one ear length, or 6.5 to 7.5 cm. On the right side the position are at 7, 9 and 11 o’clock position and on left side the corresponding positions are at 1, 3 and 5 o’clock.
ATTACHMENTS USED
Gold alloy bar, magnets, magnet keeper that connects directly to the abutments.
BONE ANCHORED HEARING AIDS (BAHA)
In this the sound conduction is through the bone directly to the internal ear.
FIGURE – V BONE ANCHORED HEARING AIDS (BAHA)
FIGURE - VI INNEREAR DIAGRAM SHOWING MECHANISM OF ACTION OF BONE ANCHORED HEARING AIDS (BAHA)
ORBITAL DEFECTS – IMPLANT DESIGNS4,5
Problems associated with adhesives in the temporal region are more prevalent in the orbit. For an orbital prosthesis the implants -
- Easy application and removal of the prosthesis.
- It can be repositioned quickly without fear.
- It will provide orbital aeration and improves health.
FIGURE – VII ORBITAL IMPLANTS
Implants are ideally placed around the defect, because of bone anatomy, placement is often limited to superior and lateral aspect of the rim. It is not only the position but also the direction and no. of implants that should be considered. If possible it is more favorable to have more than two fixtures placed both in the upper and lower orbital rim.
VARIOUS RETENTIVE OPTIONS
- BAR AND CLIP ATTACHMENTS
- INDIVIDUAL MAGNETS
- BALL ATTACHMENTS
- CONSOLE ATTACHMENT
NASAL DEFECTS - IMPLANTS DESIGNS
In Naso maxillary and Nasolabial defects, the total or near total resection of the nose creates functional and aesthetic problems. For
FIGURE - VIII NOSE IMPLANTS
nasal defects, implants can be placed in the maxillary & frontal bone. Implant success is highest when implants are placed in the superior surface of the maxilla and used to retain the inferior aspect of the nasal prosthesis. Generally a U shaped retentive bar connected to the implants at the base of the U will provide three points of retention, the two vertical struts and the horizontal crossbar.
MIDFACE DEFECTS – IMPLANT DESIGNS6
This can be grouped under three main categories:
Maxillary Facial defect opposing Edentulous mandible
The use of implants in conjunction with a maxillary obturator prosthesis may improve the retention and stability of the prosthesis.
Maxillary Facial defect opposing Bilateral posterior Edentulous mandible
As sufficient bone stock is present only in the posterior midface structures ( zygoma, infraorbital rim, pterygoid plates).
Maxillary facial defect with natural posterior vertical stops6
Vertical stops on natural molars and premolars may represent the most desirable occlusal condition. The use of residual maxillary dentition for stabilizing the obturator and development of an occlusion that inhibits anterior contacts may provide best opportunity for restricting obturator generator movement of the facial prosthesis.
Jensen O T et al (1992) conducted a study to identify all potential locations for implant placement in the midfacial region, and depending upon this he suggested a Craniofacial site classification for the Osseointegrated Implants :
- Alpha sites,
- Beta sites,
- Delta sites.
FOLLOW UP MANAGEMENT
Follow up management is very important to maintain the health of the implants & surrounding soft tissue. Regular recall visits.
SUMMARY
Patients with facial defects will seek treatment to address the loss of comfort, function or natural appearance. It is the maxillofacial prosthodontists responsibility to provide prosthesis that do not injure the remaining structures.
REFERENCES
- Branemark P.-I.: Extraoral applications of osseointegration, Quintessence Books, 1993.
- Ismail J.Y.H., & Zaki H.M.: Osseointegration in Maxillofacial prosthetics. DCNA 1990; 34: 327-41
- John Y.: Ossoeintegration in maxillofacial prosthesis. DCNA: 1990;34:2:327.
- Bergstrom K: Prosthetic techniques for orbital defects. Nobelpharma Intermational updates 2.93, Pg. nos. 5-8.
- Branemark P.-I., Oliveira M.F.D.:Craniofacial prosthesis, Quintessence Publications, 1997.
- Jensen D.T., Brownd C & Blacker J: Nasofacial prosthesis supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992; 7: 203-11.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr Sejal Shah. Implants Retained Maxillofacial Prosthesis - a Glimse into Future. Guident. 2014 Jul;7(8). Available from: https://ivoryindia.in/articles/implantology/implants-retained-maxillofacial-prosthesis-a-glimse-into-future.html















